A histologic and mechanical evaluation of carbon-coated polyester suture
- 31 October 1986
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 20 (9) , 1347-1357
- https://doi.org/10.1002/jbm.820200909
Abstract
Ultra low temperature isotropic (ULTI) carbon‐coated polyester suture material was evaluated histologically and mechanically in dogs. These results were compared to those obtainedfor uncoated polyester and polybutylate coated polyester. The suture materials were used in therepair of the surgically incised medical collateral ligament and subcutaneous tissues to evaluate the potential of the carbon‐coated system for ligamentous repairs. Following surgery, the dogs were sacrificed at periods of 1–48 weeks postoperatively for evaluation of tissue biocompatibility and mechanical strength of the materials. The polybutylate‐coated polyester suture broke at lower force levels than did comparable sizes of uncoated or carbon‐coated polyester. All three types showed a high retention (>98%) of mechanical strength at 48weeks, often exhibiting an increase in tensile strength due to tissue ingrowth. The histologic response to carbon‐coated polyester was equal to or better than the response to either the uncoated polyester or polybutylate‐coated polyester. A greater degree of tissue growth into the carbon‐coated material was evident at most time periods following an initial acute inflammatory response which was also present in the other materials.This publication has 14 references indexed in Scilit:
- The Use of Carbon Fiber Implants in Anterior Cruciate Ligament SurgeryPublished by Wolters Kluwer Health ,1985
- Ligament Replacement with an Absorbable Copolymer Carbon Fiber Scaffold-Early Clinical ExperienceClinical Orthopaedics and Related Research, 1985
- Comparison of the structure of neotendons induced by implantation of carbon or polyester fibresThe Journal of Bone and Joint Surgery. British volume, 1984
- Two cases of incompatibility to carbon-coated subperiosteal implantsOral Surgery, Oral Medicine, Oral Pathology, 1982
- Biologic Response to SuturesOtolaryngology -- Head and Neck Surgery, 1980
- Five Year Study of Tissue Reaction to Synthetic SuturesAnnals of Surgery, 1979
- CARBON IN PROSTHETICSAnnals of the New York Academy of Sciences, 1977
- Induction of tendon and ligament formation by carbon implantsThe Journal of Bone and Joint Surgery. British volume, 1977
- Long-Term Comparative Study of Nonabsorbable SuturesAnnals of Surgery, 1970
- Comparative Reaction of Mersilene and Silk Sutures Implanted Within the Heart*Annals of Surgery, 1961