Progressive muscular dystrophy (Duchenne): Biochemical studies by flow-cytometry
- 1 April 1985
- journal article
- research article
- Published by Springer Nature in Human Genetics
- Vol. 69 (4) , 332-336
- https://doi.org/10.1007/bf00291651
Abstract
The peanut lectin (PNL) receptor density of the cell membrane and several metabolic parameters of cultured fibroblasts of normal human individuals and of patients with muscular dystrophy were measured by simultaneous two and three parameter flow cytometry. The PNL-receptor density was significantly decreased on muscular dystrophy fibroblasts (between 20.7 and 33.6%) as compared to normal fibroblasts. The cell volume, the esterase activity, the intracellular pH, and the percentage of proliferating cells of both types of fibroblasts were not significantly altered. The mean cell volume of different fibroblast cultures varied between 2500 and 6000μm3. The concentration of the intracellular esterase activity of fibroblasts was low (0.169 relative units) as compared to lymphocytes and granulocytes of the peripheral blood (1.56 and 2.17 relative units). The fibroblasts had an acidic intracellular pH of 6.52 while lymphocytes and granulocytes had basic pH values of 7.30 and 7.17. Some of the fibroblasts were in the S+G2/M phase of the cell cycle (20%). The study shows that the measurement of biochemical parameters of vital and fixed single fibroblasts by flow-cytometry is of great interest for the recognition of differences between normal individuals and muscular dystrophy patients.Keywords
This publication has 12 references indexed in Scilit:
- “Cytomic” data system modules—modern electronic devices for flow cytometric data handling and presentationCytometry, 1984
- Duchenne muscular dystrophy: Pathogenetic aspects and genetic preventionHuman Genetics, 1984
- A cell surface abnormality in Duchenne muscular dystrophy: Intercellular adhesiveness of skin fibroblasts from patients and carriersHuman Genetics, 1983
- Membrane abnormalities in Duchenne muscular dystrophyJournal of the Neurological Sciences, 1983
- Fast intracellular pH determination in single cells by flow-cytometryThe Science of Nature, 1981
- Flow cytometric determination of esterase and phosphatase activities and kinetics in hematopoietic cells with fluorogenic substratesCytometry, 1980
- LYMPHOCYTE CAPPING IN DUCHENNE MUSCULAR DYSTROPHYThe Lancet, 1979
- Lymphocyte Capping in Duchenne Muscular DystrophyNew England Journal of Medicine, 1979
- Fluvo-metricell, a combined cell volume and cell fluorescence analyzer.Journal of Histochemistry & Cytochemistry, 1977
- Erythrocyte Deformation in Human Muscular DystrophyScience, 1974