Digital angiographic impulse response analysis of regional myocardial perfusion. Estimation of coronary flow, flow reserve, and distribution volume by compartmental transit time measurement in a canine model.
- 1 March 1991
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 68 (3) , 870-880
- https://doi.org/10.1161/01.res.68.3.870
Abstract
A system impulse response function that describes the kinetics of radiographic contrast material transit through the coronary circulation was calculated from 175 selective digital angiograms of normal and stenotic arteries in 10 dogs during rest and hyperemia. The goal of the study was to determine if the flow and distribution volume characteristics of the epicardial coronary arteries and the myocardial microcirculation could be stimulated by specific mathematical compartments of a lagged normal density model impulse response function in which the flow/distribution volume ratio is the inverse of the mean transit time. The arterial compartment mean transit time correlated with flow (r = 0.75); however, the correlation was significantly improved in individual dogs (r = 0.83 +/- 0.13; p less than 0.005) and was highly dependent on the length of the conduit vessel. The microcirculation compartment mean transit time was distributed as two populations with respect to flow. There was a linear correlation during hyperemia (r = 0.87) and a nonlinear relation during rest, which was characteristic of an autoregulating system. Resting values of microcirculation compartment mean transit time correlated with coronary flow reserve (r = 0.84) and differed significantly between vessels that were normal and those with subcritical stenosis, critical stenosis, or total occlusion (p less than 0.01 for all comparisons). The estimated microcirculation compartment distribution volume increased from a minimum of 4.0 +/- 1.5 ml/100 g myocardium in normal vessels with resting flow to 11.2 +/- 3.5 ml/100 g during hyperemia. These data suggest that the model compartments functionally describe the physiological behavior of their anatomic analogues and permit the quantification of microcirculatory autoregulation from a single measurement at rest without provoking hyperemia.Keywords
This publication has 18 references indexed in Scilit:
- Comparison by quantitative angiographic assessment of coronary stenoses of one view showing the severest narrowing to two orthogonal viewsThe American Journal of Cardiology, 1989
- Quantitative evaluation of regional myocardial blood flow by videodensitometric analysis of digital subtraction coronary arteriography in humansJournal of the American College of Cardiology, 1986
- Comparing the Means of Several GroupsNew England Journal of Medicine, 1985
- Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterizationThe American Journal of Cardiology, 1985
- Application of digital techniques to selective coronary arteriography: Use of myocardial contrast appearance time to measure coronary flow reserveAmerican Heart Journal, 1984
- Hemodynamic and electrocardiographic effects in man of a new nonionic contrast agent (iohexol): Advantages over standard ionic agentsThe American Journal of Cardiology, 1983
- The Diagnostic Potential of Contrast Enhancement PharmacokineticsInvestigative Radiology, 1978
- Comparative Efficacy of Coronary Vasodilatory MethodsInvestigative Radiology, 1977
- The flow-structure in packed bedsChemical Engineering Science, 1958