Evaluation of cardiopulmonary devices on chest radiographs: digital vs analog radiographs
- 1 December 1989
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 153 (6) , 1165-1168
- https://doi.org/10.2214/ajr.153.6.1165
Abstract
We compared digital and analog radiographs of the chest for use in detecting and evaluating a variety of cardiopulmonary devices in 40 patients. The devices included 23 endotracheal tubes, 21 Swan-Ganz catheters, 14 central venous pressure catheters, 11 prosthetic valves, 10 chest tubes, six pacemaker wires, and five intraaortic balloon pumps. Each patient had at least one device, with a maximum of five devices (average, 2.3). Forty digital/analog film pairs were compared by five radiologists, who assigned confidence levels for various judgments about each device. The results showed that there were no statistically significant differences in the identification of the devices except for prosthetic valves (all valves were detected on digital radiographs, compared with 62% on analog radiographs). The devices were detected on 96% of the digital radiographs and 90% of the analog radiographs. Although digital and analog radiographs were comparable for detection of most devices, the digital radiographs allowed greater confidence in the identification of the devices and in the identification of the tip and course of Swan-Ganz and central venous pressure catheters.This publication has 9 references indexed in Scilit:
- Pneumothorax and other lung diseases: effect of altered resolution and edge enhancement on diagnosis with digitized radiographs.Radiology, 1988
- Effects of image processing on nodule detection rates in digitized chest radiographs: ROC study of observer performance.Radiology, 1988
- Digital radiography in an intensive care unitClinical Radiology, 1988
- Megavoltage portal films using computed radiographic imaging with photostimulable phosphorsMedical Physics, 1987
- Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules.Radiology, 1986
- Digital and conventional chest images: observer performance with Film Digital Radiography System.Radiology, 1986
- Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.Radiology, 1986
- Spatial resolution requirements for digital chest radiographs: an ROC study of observer performance in selected cases.Radiology, 1986
- Computed radiography utilizing scanning laser stimulated luminescence.Radiology, 1983