The source of ultrasound contrast effect
- 1 April 1980
- journal article
- research article
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 8 (2) , 121-127
- https://doi.org/10.1002/jcu.1870080205
Abstract
Evidence that microbubbles are the main sources of ultrasound contrast in injected solutions has been largely indirect. To investigate this directly, we examined freshly agitated indocyanine green, freshly agitated water, commercially prepared precision microbubbles (diameter 75 ± 25 μ) in gelatin, carbonated water, “degassed” indocyanine green solution, and “degassed” water in one or more of four different assay systems. Only fluids with microbubbles produced ultrasound contrast. Injected contrast material rose in a water bath at a rate that identified it as being caused by microbubbles. Indocyanine green and gelatin surface tensions were measured and found to be low (43 dynes/cm2), thus explaining their tendency to stabilize the microbubbles that cause ultrasound contrast effect when injected and to hold foam after agitation. The force of hand injections (force similar to that used clinically through catheters and 19-gauge or 23-gauge needles) was below the force needed to cause cavitation or ultrasound contrast effect. Microbubble content could be quantified by the decrease in amplitude of the echo from a structure distant to the microbubbles. We conclude that the ultrasound contrast effect seen in peripherally injected fluids is caused by microbubbles present in the injectant. The contrast is not due to cavitation at needle tips, and it can be quantified over a limited range. Improved design for a peripheral contrast agent is suggested.Keywords
This publication has 9 references indexed in Scilit:
- Decompression Studies Using Ultrasonic Imaging of BubblesIEEE Transactions on Biomedical Engineering, 1978
- Indicator-dilution curves obtained by photometric analysis of two-dimension echo-contrast studiesThe American Journal of Cardiology, 1978
- Counting bubbles acoustically: a reviewUltrasonics, 1977
- Intracavitary echoes in patients with mitral prosthetic valvesJournal of Clinical Ultrasound, 1975
- Contrast Agents for Diagnostic UltrasoundInvestigative Radiology, 1972
- ULTRASONIC DETECTION OF CAVITATION AT CATHETER TIPSAmerican Journal of Roentgenology, 1970
- Ultrasound Cardiography: Contrast Studies in Anatomy and FunctionRadiology, 1969
- Echocardiography of the Aortic RootInvestigative Radiology, 1968
- Cavitation at Catheter TipsInvestigative Radiology, 1968