Accuracy of exercise electrocardiography in detecting physiologically significant coronary arterial lesions.
- 1 February 1991
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 83 (2) , 412-421
- https://doi.org/10.1161/01.cir.83.2.412
Abstract
The accuracy of exercise electrocardiography in detecting a physiologically significant coronary artery stenosis has been assessed previously by comparing the exercise test with a coronary arteriogram. The inherent inaccuracy of visually determined percent diameter stenosis measurements might have lead to the conclusion that the exercise electrocardiogram was less accurate than it truly was. To determine the accuracy of the exercise electrocardiography in detecting a physiologically significant coronary stenosis, we studied 40 patients with one-vessel, one-lesion coronary artery disease, a normal resting electrocardiogram, and no hypertrophy or prior infarction. Each patient underwent exercise electrocardiography (Bruce protocol) that was interpreted as abnormal if the ST segment developed 0.1-mV or greater depression 80 msec after the J point. The physiological significance of each coronary stenosis was assessed by measuring of coronary flow reserve (peak divided by resting blood flow velocity) in the stenotic artery using a Doppler catheter and intracoronary papaverine (normal, 3.5 or greater peak/resting velocity). The percent diameter and percent area stenosis produced by each lesion were determined using quantitative angiography (Brown/Dodge method). Of the 17 patients with reduced coronary flow reserve (3.5 or greater peak/resting blood flow velocity) in the stenotic artery, 14 had an abnormal exercise electrocardiogram (sensitivity, 0.82; 95% confidence interval, 0.70-0.94). Conversely, 20 of 23 patients with normal coronary flow reserves had normal exercise tests (specificity, 0.87; 95% confidence interval, 0.77-0.97). The exercise electrocardiogram was abnormal in each of 11 patients with markedly reduced coronary flow reserve (less than 2.5 peak/resting velocity) and in three of six patients with moderately reduced reserve (2.5-3.4 peak/resting velocity). The products of systolic blood pressure and heart rate at peak exercise were significantly correlated with coronary reserve in patients with truly abnormal exercise tests. In comparison, the sensitivity (0.61; 95% confidence interval, 0.46-0.76) and specificity (0.73; 95% confidence interval, 0.60-0.86) of exercise electrocardiography in detecting a 60% or greater diameter stenosis may be significantly lower (p less than 0.05). Exercise electrocardiography, therefore, was a good predictor of the physiological significance (assessed by coronary flow reserve) of a coronary stenosis in patients with a normal resting electrocardiogram and no hypertrophy or prior infarction. Its value in a broader and larger patient population will require further study. These results, however, underscore the importance of a physiological gold standard in assessing the accuracy of noninvasive studies for detecting coronary artery disease.Keywords
This publication has 32 references indexed in Scilit:
- Delineation of the Extent of Coronary Atherosclerosis by High-Frequency Epicardial EchocardiographyNew England Journal of Medicine, 1987
- Diltiazem-induced blockade of sympathetically mediated constriction of normal and diseased coronary arteries: lack of epicardial coronary dilatory effect in humans.Circulation, 1984
- The value of lesion cross-sectional area determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending coronary arterial stenoses.Circulation, 1984
- Does Visual Interpretation of the Coronary Arteriogram Predict the Physiologic Importance of a Coronary Stenosis?New England Journal of Medicine, 1984
- Coronary dilatory capacity in idiopathic dilated cardiomyopathy: Analysis of 16 patientsThe American Journal of Cardiology, 1983
- Diagnostic accuracy of exercise ECG lead systems in clinical subsets of women.Circulation, 1982
- The electrocardiographic response to maximal treadmill exercise of asymptomatic men with left bundle branch blockAmerican Heart Journal, 1977
- Graded Exercise Stress Tests in Angiographically Documented Coronary Artery DiseaseCirculation, 1974
- Correlation of computer-quantitated treadmill exercise electrocardiogram with arteriographic location of coronary artery diseaseThe American Journal of Cardiology, 1972
- ELECTROCARDIOGRAPHIC CHANGES DURING ATTACKS OF ANGINA PECTORISThe Lancet Healthy Longevity, 1928