Progress toward a microradiation therapy small animal conformal irradiator
- 26 September 2006
- journal article
- Published by Wiley in Medical Physics
- Vol. 33 (10) , 3834-3845
- https://doi.org/10.1118/1.2349693
Abstract
Microradiation therapy (microRT) systems are being designed to provide conformal radiation therapy to small animals enabling quantitative radiation response evaluation. We used a Monte Carlo approach to estimate the radiation dose distributions from proposed blueprints and developed a beam model to aid in the microRT system design process. This process was applied to a prototype irradiator that uses a small (3 mm long and 3 mm in diameter), cylindrical, high-activity 192Ir source delivering the radiation beam using custom-fabricated tungsten collimators. The BEAMnrc Monte Carlo code was used to simulate dose distributions from these prototype collimators. Simulations were performed at three source-to-surface distances (50, 60, and 70 mm), and with five circular field sizes (5, 7.5, 10, 12.5, and 15 mm). A dose to a 50 X 50 X 50 mm3 water phantom with 1 X 1 X 1 mm3 voxel spacing was computed. A multiparameter dose calculation algorithm was developed to efficiently and accurately calculate doses for treatment planning exercises. The parametrization was selected so that the parameters varied smoothly as a function of depth, source-to-surface distance, and field size, allowing interpolation for geometries that were not simulated using the Monte Carlo simulation. Direct comparison of the model with the Monte Carlo simulations showed that the variations were within 5% error for field sizes larger than 10 mm, and up to 10% for smaller field sizes.Keywords
This publication has 8 references indexed in Scilit:
- Use of the Leksell Gamma Knife for Localized Small Field Lens Irradiation in RodentsTechnology in Cancer Research & Treatment, 2003
- Evaluation of the gamma dose distribution comparison methodMedical Physics, 2003
- Correlation of Tumor Oxygen Dynamics with Radiation Response of the Dunning Prostate R3327-HI Tumor1Radiation Research, 2003
- Gene Transfer of Human Manganese Superoxide Dismutase Protects Small Intestinal Villi From Radiation InjuryJournal of Gastrointestinal Surgery, 2003
- Partial volume rat lung irradiation; assessment of early DNA damage in different lung regions and effect of radical scavengersRadiotherapy and Oncology, 2003
- Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributionsMedical Physics, 2000
- Partial volume rat lung irradiation: An evaluation of early DNA damageInternational Journal of Radiation Oncology*Biology*Physics, 1998