Dosimetry techniques for narrow proton beam radiosurgery
- 20 October 1999
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (11) , 2789-2801
- https://doi.org/10.1088/0031-9155/44/11/308
Abstract
Characterization of narrow beams used in proton stereotactic radiosurgery (PSRS) requires special efforts, since the use of finite size detectors can lead to distortion of the measured dose distributions. Central axis depth doses, lateral profiles and field size dependence factors are the most important beam characteristics to be determined prior to dosimetry calculations and beam modelling for PSRS. In this paper we report recommendations for practical dosimetry techniques which were developed from a comparison of beam characteristics determined with a variety of radiation detectors for 126 and 155 MeV narrow proton beams shaped with 2-30 mm circular brass collimators. These detectors included small-volume ionization chambers, a diamond detector, an Hi-p Si diode, TLD cubes, radiographic and radiochromic films. We found that both types of film are suitable for profile measurements in narrow beams. Good agreement between depth dose distributions measured with ionization chambers, diamond and diode detectors was demonstrated in beams with diameters of 20-30 mm. The diode detector can be used in smaller beams, down to 5 mm diameter. For beams with diameters less than 5 mm, reliable depth dose data may be obtained only with radiochromic film. The tested ionization chambers are appropriate for calibration of beams with diameters of 20-30 mm. TLD cubes and diamond detectors are useful to determine relative dose in beams with diameters of 10-20 mm. Field size factors for smaller beams should be obtained with diode and radiochromic film. We conclude that dosimetry characterization of proton beams down to several millimetres in diameter can be performed using the described procedures.Keywords
This publication has 13 references indexed in Scilit:
- Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgeryPhysics in Medicine & Biology, 1997
- Radiochromic film dosimetry for clinical proton beamsApplied Radiation and Isotopes, 1997
- Proton dosimetry intercomparisonRadiotherapy and Oncology, 1996
- A comparison of dosimetry techniques in stereotactic radiosurgeryPhysics in Medicine & Biology, 1996
- A review of proton beam radiation therapyMedical Physics, 1995
- Application of solid state detectors for dosimetry of therapeutic proton beamsMedical Physics, 1995
- Multiple Coulomb scattering of 160 MeV protonsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1993
- Stopping powers for the ion-chamber dosimetry of radiotherapeutic heavy-particle beamsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1992
- Equipment for Radiation Surgery Using Narrow 185 MeV Proton Beams: Dosimetry and designActa Oncologica, 1987
- Bragg-Peak Proton-Beam Therapy for Arteriovenous Malformations of the BrainNew England Journal of Medicine, 1983