An investigation into techniques for reducing doses from neo-natal radiographic examinations
- 1 October 1995
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 68 (814) , 1074-1082
- https://doi.org/10.1259/0007-1285-68-814-1074
Abstract
A survey of radiation doses received by infants having radiography in a neo-natal unit was undertaken at Aberdeen Maternity Hospital. Options for dose reduction recommended by the CEC Lake Starnberg Group were investigated. Techniques were implemented for clinical evaluation after assessments of image quality with test objects and phantoms. Clinical image quality of radiographs was evaluated by paediatric radiologists using CEC criteria. Results revealed a clear relationship between entrance dose and patient weight, indicating that reference doses for infants could be linked to weight. At the start of the study the mean entrance dose for chest anteroposterior (AP) radiographs was 65 microGy and the dose-area product 12.3 mGy cm2 for a system with 2.5 mm aluminum filtration using 50 kVp X-rays with a 200 speed class film/screen system. A 400 speed class film/screen combination was investigated but not evaluated clinically, because the image quality was not considered acceptable. Addition of 0.1 mm copper to the filtration of the X-ray tube reduced entrance doses by 50%, but the technique was not adopted, because of a poorer image quality with only 72% of features in clinical images being reproduced to an acceptable standard, compared with 87% with the original system. Use of faster processing chemicals, an increase in filtration to 3.5 mm aluminium and a tube potential of 60 kVp resulted in a 40% reduction in mean entrance dose to 37 microGy with satisfactory clinical image quality.Keywords
This publication has 12 references indexed in Scilit:
- A study of the relationship between patient dose and size in paediatric radiologyThe British Journal of Radiology, 1994
- Energy imparted to neonates during X-ray examinations in a special care baby unitThe British Journal of Radiology, 1994
- Implementation of a programme for reduction of radiographic doses and results achieved through increases in tube potentialThe British Journal of Radiology, 1993
- Conversion Factors between Energy Imparted to the Patient and Air Collision Kerma Integrated Over Beam Area in Pediatric RadiologyActa Radiologica, 1993
- Dose reduction by the use of erbium filtration in a general radiographic roomThe British Journal of Radiology, 1992
- Comparison of performance characteristics of conventional and K-edge filters in general diagnostic radiologyPhysics in Medicine & Biology, 1989
- Radiation dose to neonates on a Special Care Baby UnitThe British Journal of Radiology, 1989
- The influence of tube filtration and potential on patient dose during X-ray examinationsPhysics in Medicine & Biology, 1988
- The risk of diagnostic radiation of the newbornThe British Journal of Radiology, 1986
- A Practical Method for Monitoring Diagnostic Radiation Dosage in the Newborn NurseryRadiology, 1979