A Diagnostic Method for Time Resolved Spatial Profile Measurements of Proton and Impurity Density and Temperature
- 1 June 1978
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 6 (2) , 107-120
- https://doi.org/10.1109/tps.1978.4317101
Abstract
A new diagnostic technique, based on elastic scattering of neutral atoms off the plasma ions, is proposed and analyzed. Space and time resolved measurements of the number densities and temperatures of the various components of the plasma are possible by energy analysis of the scattered neutral atoms. The ability to resolve ions of different masses is limited by ion thermal motion and the energy and angular dependence of the scattering cross sections. In hydrogenic plasmas with impurities, the scattering by the impurities is easily resolvable from the scattering of protons, even when the individual impurity contributions cannot be separately resolved. Detected particle count rates are calculated for a conceputal system for a tokamak plasma (n ~ 1013 cm-3, Ti ~ 300 eV). Time resolution of ~ 10 ms with spatial resolution of a few cm are predicted.Keywords
This publication has 8 references indexed in Scilit:
- Differential and integral cross sections for proton-hydrogen scatteringJournal of Physics B: Atomic and Molecular Physics, 1976
- Common trajectory methods for the calculation of differential cross sections for inelastic transitions in atom(ion)-atom collisions. II. Application to proton-hydrogen scatteringJournal of Physics B: Atomic and Molecular Physics, 1975
- An improved retarding field analyserJournal of Physics E: Scientific Instruments, 1972
- A calibrated neutral atom spectrometer for measuring plasma ion temperatures in the 0.165- to 10-keV energy regionNuclear Fusion, 1972
- Numerical ion trajectory calculations in and measurements on a Daly type conversion detectorJournal of Physics E: Scientific Instruments, 1970
- Ionization and Electron Transfer in Collisions of Two H Atoms: 1.25-117 keVPhysical Review B, 1968
- Transformations and Averaging Processes for Differential Cross-Section Measurements at Thermal EnergiesThe Journal of Chemical Physics, 1968
- Scintillation Type Mass Spectrometer Ion DetectorReview of Scientific Instruments, 1960