Improved assessment of minimal residual disease in B cell malignancies using fluorogenic consensus probes for real-time quantitative PCR
Open Access
- 1 August 2000
- journal article
- research article
- Published by Springer Nature in Leukemia
- Vol. 14 (8) , 1419-1425
- https://doi.org/10.1038/sj.leu.2401831
Abstract
PCR of clonally rearranged immunoglobulin heavy chain (IgH) gene sequences is increasingly used for detection of minimal residual disease (MRD) in lymphoid malignancies. Inherent quantitating problems are the main drawbacks of traditional PCR technologies. These limitations have been overcome by the recently developed real-time quantitative PCR (RQ PCR) technology. However, clinical application of the few published RQ PCR assays targeting immune gene rearrangements is hampered by the expensive and time-consuming need for individual hybridization probes for each patient. We have developed a new RQ PCR strategy targeting clonally rearranged IgH sequences that solves this problem. The method uses only two different JHhybridization probes and four downstream JH primers homologous to consensus germline JH gene segments. In combination with an allele-specific upstream (ASO) primer the consensus JH probes and primers allow quantitation of about 90% of possible IgH rearrangements. In a series of 22 B-lineage ALL the new assay allowed the detection of one to 10 blasts in a background of 105 normal cells. To prove the clinical utility we quantified MRD in 23 follow-up samples of six ALL patients with the new assay in comparison with a published RQ PCR technique that used individually designed primer/probe sets. We showed that the sensitivity of the new RQ PCR assay was slightly higher for four of the six cases and about 100-fold higher for one case, enabling detection of an increasing MRD level as an indicator of subsequent relapse 44 weeks earlier compared to the ASO probe assay in this particular patient. The results suggest, that the novel RQ PCR assay is a rapid, technically simple, reliable, and sensitive alternative to traditional quantification assays and simplifies current approaches of monitoring MRD in clinical trials.Keywords
This publication has 30 references indexed in Scilit:
- INVESTIGATION OF MINIMAL RESIDUAL DISEASE IN CHILDHOOD AND ADULT ACUTE LYMPHOBLASTIC LEUKAEMIA BY MOLECULAR ANALYSISBritish Journal of Haematology, 1999
- Prognostic value of minimal residual disease in acute lymphoblastic leukaemia in childhoodThe Lancet, 1998
- Novel 5′ Exonuclease-Based Real-Time PCR Assay for the Detection of t(14;18)(q32;q21) in Patients with Follicular LymphomaThe American Journal of Pathology, 1998
- Sequence of the human immunoglobulin diversity (D) segment locus: a systematic analysis provides no evidence for the use of DIR segments, inverted D segments, “minor” D segments or D-D recombination 1 1Edited By J. KarnJournal of Molecular Biology, 1997
- Quantitative PCR of the immunoglobulin heavy chain gene using genomic DNABritish Journal of Haematology, 1996
- A novel method for real time quantitative RT-PCR.Genome Research, 1996
- Real time quantitative PCR.Genome Research, 1996
- Extensive allelic sequence variation in the J region of the human immunoglobulin heavy chain gene locusEuropean Journal of Immunology, 1995
- Immunoglobulin heavy chain gene expression in peripheral blood B lymphocytes.Journal of Clinical Investigation, 1992
- Follow-up of residual disease (MRD) in B lineage acute leukaemias using a simplified PCR strategy: evolution of MRD rather than its detection is correlated with clinical outcomeBritish Journal of Haematology, 1991