Abstract
An analytic method for detecting isodense subdural fluid collections from computed tomography (CT) scan pixel attenuation data is presented. Analysis of 44 CT scan levels from 8 patients with isodense subdural hematomas (ISDH) and 50 CT scan levels from 15 patients without ISDH indicates 6% false positive and 3% false negative errors if the analysis is restricted to noncontrast CT scans that demonstrate subcalvarial bilateral cortical attenuation symmetry in the pictorial display.This publication has 6 references indexed in Scilit:
- The Grain in the Stone: A Computer Search for Hidden CT PatternsRadiology, 1978
- Computed Tomography in Isodense Subdural HematomaRadiology, 1978
- Statistical Profiles in Computed TomographyRadiology, 1977
- Factors Affecting the Use of Quantitative Information from a CT ScannerRadiology, 1977
- Computed Tomography in Head TraumaRadiology, 1977
- Attenuation Measurements of Whole Blood and Blood Fractions in Computed TomographyRadiology, 1976