Systemic and Regional Hemodynamics Assessment in Rats with Fluorescent Microspheres
- 1 March 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cardiovascular Pharmacology
- Vol. 33 (3) , 425-432
- https://doi.org/10.1097/00005344-199903000-00013
Abstract
The aim of this study was to validate in rats an alternative to the radioactive microspheres (RM) reference technique, the fluorescent microspheres (FM), for the simultaneous determination of cardiac index (CI) and regional blood flows (RBF). Validation of the FM method was performed in three steps: (a) comparison of CI and RBF values obtained simultaneously by FM and RM, (b) determination of the repeatability of the measurements by using two successive injections of FM, and (c) evaluation of the ability of the FM method to assess vasodilating effects (by using dipyridamole). CI values (range, 242-513 ml/min·kg; n = 20) obtained with FM correlated with those obtained with RM (r = 0.82; p < 0.001), and agreement was found between FM and RM (error 95% confidence interval for one pair, ±125 ml/min·kg). FM RBF values, although smaller than corresponding RM RBF values, were correlated with the latter (range, 0.1-7 ml/min·g; n = 71; r = 0.99; p < 0.001). Agreement was dependent on RBF values, e.g., error 95% confidence intervals for one pair were 0.08-0.13 and 3.86-6.48 for 0.1 and 5 ml/min·g, respectively. Two successive FM injections at a 10-min interval (conscious rats) provided similar values (n = 14) for CI (306 ± 24 vs. 346 ± 18 ml/min·kg), and renal (5.1 ± 0.2 vs. 6.2 ± 0.3 ml/min·g), left (6.1 ± 0.3 vs. 5.8 ± 0.4 ml/min·g) and right (4.8 ± 0.4 vs. 4.7 ± 0.3 ml/min·g) myocardial RBF. Corresponding error 95% confidence intervals were ± 187 ml/min·kg, ±2.8, ±2.2, and ±2.0 ml/min·g, respectively. Dipyridamole (2, 4, 6, and 8 mg/kg·min for 10 min, i.v.; n = 9-13 per group, conscious rats) significantly and dose dependently increased left and right myocardial blood flows, whereas renal blood flow was not affected. We conclude that the FM technique (a) is reliable and in agreement with the RM method, (b) provides repeatable measurements of systemic and regional hemodynamics, and (c) allows detection and quantification of vasodilating effects in rats.Keywords
This publication has 11 references indexed in Scilit:
- Voltage-dependent potentiation of neuronal L-type calcium channels due to state-dependent phosphorylationAmerican Journal of Physiology-Cell Physiology, 1995
- Measurement of organ blood flow with coloured microspheres in the ratCardiovascular Research, 1995
- Comparative effects of chronic angiotensin-converting enzyme inhibition and angiotensin II type 1 receptor blockade on cardiac remodeling after myocardial infarction in the rat.Circulation, 1994
- Validation of fluorescent-labeled microspheres for measurement of regional organ perfusionJournal of Applied Physiology, 1993
- Measurement of regional myocardial blood flow with multiple colored microspheres.Circulation, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Effects of duration and severity of arterial hypertension and cardiac hypertrophy on coronary vasodilator reserve.Circulation Research, 1982
- Simultaneous measurement of cardiac output and its distribution with microspheres in the ratCardiovascular Research, 1976
- Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized DogsCirculation Research, 1969
- The Circulation of the Fetus in UteroCirculation Research, 1967