The double mask-a new local scavenging system for anaesthetic gases and volatile agents
- 1 April 1986
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 30 (3) , 260-265
- https://doi.org/10.1111/j.1399-6576.1986.tb02409.x
Abstract
The double mask, a new concept for local scavenging of anaesthetic gases escaping around face masks and from endotracheal tubes, is described. The system consists of a flexible silicone mask into which the anaesthetic gas mixture is led through a flow distributor which is necessary for adequate scavenging. A rigid transparent polysulphone shell surrounds the inner mask, and escaping gas is evacuated via the 3-4 mm slot between the two masks by a fan, centrally located outside the operating-room. With this system, the anaesthetist''s exposure to nitrous oxide during mask anaesthesia was reduced from 145 .+-. 29 to 15 .+-. 3 ppm (mean .+-. s.e. mean, P < 0.001) and to halothane from 2.9 .+-. 1.1 to 0.5 .+-. 0.1 ppm (mean .+-. s.e. mean, P < 0.05), as measured in 32 patients aged 1-74 years. The double-mask system provided safe and adequate mask anaesthesia, as judged from inspired concentrations of anaesthetic and fresh gases and transcutaneous and blood gases in 24 patients. The noise level was low with a mean value under regular operating-room conditions around 45 dB(A) in the low frequency range. It is concluded that using the scavenging conditions provided by the system, the Swedish limits for anaesthesiologists'' gas exposure could be reduced to the levels recommended by the US National Institute of Occupational Safety and Health (25 ppm for nitrous oxide and 0.5 ppm for halothane).Keywords
This publication has 12 references indexed in Scilit:
- The Effect of Local Scavenging on Occupational Exposure to Nitrous OxideActa Anaesthesiologica Scandinavica, 1983
- Close Scavenging of Anaesthetic Gases During Mask AnaesthesiaActa Anaesthesiologica Scandinavica, 1981
- Occupational exposure to anaesthetics in 20 hospitalsAnaesthesia, 1980
- An assessment of operating room environment air contamination with nitrous oxide and halothane and some scavenging methodsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1978
- IS THERE A HEALTH HAZARD IN ANAESTHETIC PRACTICE?British Journal of Anaesthesia, 1978
- Concentration and Elimination of Anaesthetic Gases in Operating Theatres Influence of Anaesthesia Apparatus LeakagesActa Anaesthesiologica Scandinavica, 1978
- Occupational Disease among Operating Room PersonnelAnesthesiology, 1974
- A Volume and Pressure Controlling Spill Valve Equipped for Removal of Excess Anaesthetic GasActa Anaesthesiologica Scandinavica, 1972
- MEASUREMENTS OF HALOTHANE IN THE ATMOSPHERE OF AN OPERATING THEATRE AND IN EXPIRED AIRAND BLOOD OF THE PERSONNEL DURING ROUTINE ANAESTHETIC WORKActa Anaesthesiologica Scandinavica, 1970
- Über die Mengen des Narkoseäthers in der Luft von OperationssälenMedical Microbiology and Immunology, 1929