In situ and air index measurements: influence of the deposition parameters on the shift of TiO_2/SiO_2 Fabry-Perot filters
- 1 November 1986
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 25 (21) , 3909-3915
- https://doi.org/10.1364/ao.25.003909
Abstract
We measure the refractive index of thin films of TiO2 and SiO2 for given deposition parameters. Two complementary methods are used. The first is a postdeposition technique which uses the measurements of reflectance and transmittance in air. The second, in contrast, makes use of in situ measurements (under vacuum and during the actual deposition of the layer). The differences between the values deduced from the two methods can be explained by the amount of atmospheric moisture adsorbed by films. One tries to minimize these shifts for the two materials by choosing deposition parameters. The difficulties come from the absorption losses which must be as small as possible. We use the measured refractive indices of individual layers to give good numerical prediction of the wavelength shift (observed during the admittance of air after deposition in the vacuum chamber) of the transmittance peak of multidielectric Fabry-Perot filters.Keywords
This publication has 7 references indexed in Scilit:
- Refractive index and inhomogeneity of thin filmsApplied Optics, 1984
- An improved method for the determination of the extinction coefficient of thin film materialsThin Solid Films, 1983
- Automatic determination of the optical constants of inhomogeneous thin filmsApplied Optics, 1982
- Optical thin film monitoring—Recent advances and limitationsThin Solid Films, 1981
- Refractive indices of TiO_2 films produced by reactive evaporation of various titanium–oxygen phasesApplied Optics, 1976
- Moisture penetration patterns in thin filmsThin Solid Films, 1976
- Turning Value Monitoring of Narrow-band All-dielectric Thin-film Optical FiltersOptica Acta: International Journal of Optics, 1972