The effect of grid frequency decay transients on pressurized water reactors
- 1 January 1976
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. 95 (1) , 269-274
- https://doi.org/10.1109/T-PAS.1976.32101
Abstract
This paper describes the effects of loss of reactor coolant flow as caused by power system frequency decay on a Westinghouse pressurized water reactor. A protection scheme employing measurement of coolant flow, and reactor coolant pump power supply voltage and frequency is described. Analyses are presented which provide a basis for a low frequency reactor trip setpoint which adequately protects the nuclear plant, and which does not unduly compromise plant availability.Keywords