The effect of vibration on digital blood flow
- 1 October 1980
- journal article
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 67 (10) , 708-710
- https://doi.org/10.1002/bjs.1800671009
Abstract
Summary: The effect on digital blood flow of an acute exposure to vibration has been assessed. Vibration in the frequency range 40–200 Hz reduces digital blood flow, the effect being maximal at 120 Hz. Increasing the amplitude of vibration reduces digital blood flow. The results have implications in the formulation of industrial vibration standards and in the pathophysiology of vibration-induced white finger.Keywords
This publication has 6 references indexed in Scilit:
- Vibration-induced hyperresponsiveness of arterial smooth muscle to noradrenaline with special reference to Raynaud's phenomenon in vibration diseaseCardiovascular Research, 1978
- The Effect of Vibration on Blood Flow in Skeletal Muscle in the RabbitClinical Science, 1978
- Effect of vibration on total vascular resistance in the forelimb of the dog.Journal of Applied Physiology, 1969
- RAYNAUD'S PHENOMENON IN USERS OF CHAIN SAWSThe Medical Journal of Australia, 1964
- Raynaud’s Phenomenon of Occupational OriginArchives of environmental health, 1962