In-vivo fluorescence imaging with a multivariate curve resolution spectral unmixing technique
- 1 January 2009
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 14 (6) , 064011
- https://doi.org/10.1117/1.3258838
Abstract
Spectral unmixing is a useful technique in fluorescence imaging for reducing the effects of native tissue autofluorescence and separating multiple fluorescence probes. While spectral unmixing methods are well established in fluorescence microscopy, they typically rely on precharacterized in-vitro spectra for each fluorophore. However, there are unique challenges for in-vivo applications, since the tissue absorption and scattering can have a significant impact on the measured spectrum of the fluorophore, and therefore make the in-vivo spectra substantially different to that of in vitro. In this work, we introduce a spectral unmixing algorithm tailored for in-vivo optical imaging that does not rely on precharacterized spectral libraries. It is derived from a multivariate curve resolution (MCR) method, which has been widely used in studies of chemometrics and gene expression. Given multispectral images and a few straightforward constraints such as non-negativity, the algorithm automatically finds the signal distribution and the pure spectrum of each component. Signal distribution maps help separate autofluorescence from other probes in the raw images and hence provide better quantification and localization for each probe. The algorithm is demonstrated with an extensive set of in-vivo experiments using near-infrared dyes and quantum dots in both epi-illumination and transillumination geometries.Keywords
This publication has 25 references indexed in Scilit:
- Spectral Unmixing of Multicolored Bioluminescence Emitted from Heterogeneous Biological SourcesAnalytical Chemistry, 2006
- Autofluorescence removal, multiplexing, and automated analysis methods for in-vivo fluorescence imagingJournal of Biomedical Optics, 2005
- Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal ModelsMolecular Imaging, 2004
- Multivariate Curve Resolution Methods in Imaging Spectroscopy: Influence of Extraction Methods and Instrumental PerturbationsJournal of Chemical Information and Computer Sciences, 2003
- Application of equality constraints on variables during alternating least squares proceduresJournal of Chemometrics, 2002
- Spectral unmixingIEEE Signal Processing Magazine, 2002
- Resolution of multiple green fluorescent protein color variants and dyes using two-photon microscopy and imaging spectroscopyJournal of Biomedical Optics, 2001
- Least squares algorithms under unimodality and non-negativity constraintsJournal of Chemometrics, 1998
- Assessment of new constraints applied to the alternating least squares methodAnalytica Chimica Acta, 1997
- Multicolor Spectral Karyotyping of Human ChromosomesScience, 1996