Analysis of ochratoxin A in pig kidney and rye flour using liquid chromatography tandem mass spectrometry (LC/MS/MS)
- 1 November 1999
- journal article
- research article
- Published by Taylor & Francis in Food Additives & Contaminants
- Vol. 16 (11) , 451-456
- https://doi.org/10.1080/026520399283731
Abstract
A liquid chromatography electrospray tandem mass spectrometric (LC/MS/MS) method is described for analysis and confirmation of ochratoxin A in pig kidney and rye flour using derivatization of ochratoxin A to the methyl ester. Ochratoxin A methyl(d3)ester is used as internal standard. The method works well, the detection limit is 0.02 µg/kg and the repeatability (coefficient of variation) is between 6% and 16% in the contamination range 0.5 to 8 µg/kg.Keywords
This publication has 6 references indexed in Scilit:
- Determination of aflatoxins in food using LC/MS/MSZeitschrift Für Lebensmitteluntersuchung Und -Forschung A, 1998
- An intercomparison of methods for the determination of ochratoxin a in pig kidneyFood Additives & Contaminants, 1997
- The incidence and distribution of ochratoxin A in western Canadian swineFood Additives & Contaminants, 1996
- Ochratoxin A in Danish cereals 1986–1992 and daily intake by the Danish populationFood Additives & Contaminants, 1996
- Measurement of ochratoxin A in barley extracts by liquid chromatography-mass spectrometryJournal of Chromatography A, 1987
- Determination of mycotoxins in grain by high-performance liquid chromatography and thermospray liquid chromatography—mass spectometryJournal of Chromatography A, 1987