Helical MR: Continuously moving table axial imaging with radial acquisitions
Open Access
- 24 October 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (5) , 1053-1060
- https://doi.org/10.1002/mrm.10621
Abstract
A technique for extended field of view MRI is presented. Similar to helical computed tomography, the method utilizes a continuously moving patient table, a 2D axial slice that remains fixed relative to the MRI magnet, and a radial k-space trajectory. A fully refocused SSFP acquisition enables spatial resolution comparable to current clinical protocols in scan times that are sufficiently short to allow a reasonable breathhold duration. RF transmission and signal reception are performed using the RF body coil and the images are reconstructed in real time. Experimental results are presented that illustrate the technique's ability to resolve small structures in the table-motion direction. Simulation experiments to study the steady-state response of the fully refocused SSFP acquisition during continuous table motion are also presented. Finally, whole body images of healthy volunteers demonstrate the high image quality achieved using the helical MRI approach. Magn Reson Med 50:1053–1060, 2003.Keywords
This publication has 13 references indexed in Scilit:
- Reduction of transient signal oscillations in true‐FISP using a linear flip angle series magnetization preparationMagnetic Resonance in Medicine, 2002
- Continuously moving table data acquisition method for long FOV contrast‐enhanced MRA and whole‐body MRIMagnetic Resonance in Medicine, 2002
- Whole-Body MR Imaging in 30 Seconds with Real-Time True FISP and a Continuously Rolling Table Platform: Feasibility StudyRadiology, 2001
- A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectoriesIEEE Transactions on Medical Imaging, 2001
- Undersampled projection reconstruction applied to MR angiographyMagnetic Resonance in Medicine, 2000
- Total-Body Echo-planar MR Imaging in the Staging of Breast Cancer: Comparison with Conventional Methods—Early ExperienceRadiology, 1999
- Total-body MR imaging in as little as 18 seconds.Radiology, 1997
- Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan MethodsMagnetic Resonance in Medicine, 1995
- Computed tomography scanning with simultaneous patient translationMedical Physics, 1990
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990