Abstract
Background— Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. Methods and Results— Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts) were investigated by MDCT (0.6-mm collimation, 32 detector rows, 2 focal points, 330-ms rotation) 9 to 252 months (mean, 106 months) after surgery. CABG and all native coronary arteries with a diameter of >1.5 mm were evaluated for the presence of significant stenoses (≥50% diameter reduction). Results were compared with quantitative coronary angiography. By MDCT, all CABG were evaluable and were correctly classified as occluded (n=38) or patent (n=100). Sensitivity for stenosis detection in patent grafts was 100% (16/16) with a specificity of 94% (79/84). For the per-segment evaluation of native coronary arteries and distal runoff vessels, sensitivity in evaluable segments (91%) was 86% (87/101) with a specificity of 76% (354/465). If evaluation was restricted to nongrafted arteries and distal runoff vessels, sensitivity was 86% (38/44) with a specificity of 90% (302/334). On a per-patient basis, classifying patients with at least 1 detected stenosis in a CABG, a distal runoff vessel, or a nongrafted artery or with at least 1 unevaluable segment as “positive,” MDCT yielded a sensitivity of 97% (35/36) and specificity of 86% (12/14). Conclusions— We found that 64-slice MDCT permits the evaluation of bypass grafts and the assessment of the native coronary arteries for the presence of stenosis.Keywords
This publication has 24 references indexed in Scilit:
- Non-invasive evaluation of coronary artery bypass grafts using 16-row multi-slice computed tomography with 188 ms temporal resolutionInternational Journal of Cardiology, 2006
- Usefulness of 4-, 8-, and 16-Slice Computed Tomography for Detection of Graft Occlusion or Patency After Coronary Artery Bypass GraftingThe American Journal of Cardiology, 2005
- Usefulness of Multidetector Row Spiral Computed Tomography With 64- × 0.6-mm Collimation and 330-ms Rotation for the Noninvasive Detection of Significant Coronary Artery StenosesThe American Journal of Cardiology, 2005
- Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomographyAmerican Heart Journal, 2005
- Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed TomographyJournal of the American College of Cardiology, 2005
- Follow-up of Coronary Artery Bypass Graft Patency by Multislice Computed TomographyThe American Journal of Cardiology, 2005
- Performance Evaluation of a 64-Slice CT System with z-Flying Focal SpotRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomographyJournal of the American College of Cardiology, 2004
- Estimation of Radiation Exposure in 16-Detector Row Computed Tomography of the Heart with Retrospective ECG-gatingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975