Application of the row action maximum likelihood algorithm with spherical basis functions to clinical PET imaging
- 1 February 2001
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 48 (1) , 24-30
- https://doi.org/10.1109/23.910827
Abstract
Three-dimensional (3D) reconstructions from fully 3D positron emission tomography (PET) data can yield high-quality images but at a high computational cost. The 3D row action maximum likelihood algorithm (3D RAMLA) with spherically-symmetric basis functions (blobs) has recently been modified to reconstruct multi-slice 2D PET data after Fourier rebinning (FORE) but still using 3D basis functions (2.5D RAMLA. In this study 2.5D RAMLA and 3D RAMLA were applied to several patient and phantom PET datasets to assess their clinical performance. RAMLA performance was compared to that for the reconstruction techniques in routine clinical use on the authors' PET scanners. Torso phantom and whole-body patient scans acquired on the C-PET scanner were reconstructed after FORE with filtered back-projection (FORE+FBP), the ordered subsets expectation maximization algorithm (FORE+OSEM), and FORE+2.5D RAMLA for various reconstruction parameters. The 3D Hoffman brain phantom scanned on the HEAD Penn-PET scanner was reconstructed with the 3D reprojection algorithm (3DRP) and 3D RAMLA, as well, as FORE+FBP, FORE+OSEM, and FORE+2.5D RAMLA. The authors' results demonstrate improvement of 3D and 2.5D RAMLA with blob basis functions, compared to the reconstruction methods currently in clinical use, in terms of contrast recovery and noise, especially in regions of limited statistics.Keywords
This publication has 17 references indexed in Scilit:
- 2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET dataIEEE Transactions on Medical Imaging, 2000
- Exact and approximate rebinning algorithms for 3-D PET dataIEEE Transactions on Medical Imaging, 1997
- Performance of a Fast Maximum Likelihood Algorithm for Fully 3D PET ReconstructionPublished by Springer Nature ,1996
- Practical considerations for 3-D image reconstruction using spherically symmetric volume elementsIEEE Transactions on Medical Imaging, 1996
- Efficient 3D grids for image reconstruction using spherically-symmetric volume elementsIEEE Transactions on Nuclear Science, 1995
- Evaluation of task-oriented performance of several fully 3D PET reconstruction algorithmsPhysics in Medicine & Biology, 1994
- Algebraic reconstruction techniques can be made computationally efficient (positron emission tomography application)IEEE Transactions on Medical Imaging, 1993
- Alternatives to voxels for image representation in iterative reconstruction algorithmsPhysics in Medicine & Biology, 1992
- Accelerated Iterative Reconstruction for Positron Emission Tomography Based on the EM Algorithm for Maximum Likelihood EstimationIEEE Transactions on Medical Imaging, 1986
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982