Comparison of techniques for the determination of theL2−L3XCoster-Kronig transition probability
- 1 March 1975
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review A
- Vol. 11 (3) , 1093-1096
- https://doi.org/10.1103/physreva.11.1093
Abstract
The value of the Coster-Kronig transition probability for has been determined by eight variations of the x-ray coincidence technique. The effect of a correction for unwanted coincidence events in the coincidence spectrum is discussed. The value reported for the Coster-Kronig transition probability at , , is a weighted average of measurements not involving this correction. This value is in excellent agreement with previous measurements but deviates significantly from theoretical predictions.
Keywords
This publication has 6 references indexed in Scilit:
- Experimental determination of theL2−L3XCoster-Kronig transition probability in europium, plutonium, and curiumPhysical Review A, 1975
- X-Ray Fluorescence Yields, Auger, and Coster-Kronig Transition ProbabilitiesReviews of Modern Physics, 1972
- Reevaluation of-Subshell Coster-Kronig Transition Probability and Fluorescence Yield belowPhysical Review A, 1971
- Theoretical - and -Subshell Fluorescence Yields and Coster-Kronig Transition ProbabilitiesPhysical Review A, 1971
- Atomic L-Shell Coster-Kronig, Auger, and Radiative Rates and Flourescence Yields for Na-ThPhysical Review A, 1971