A Simplified Technique for Cannulation of the Jugular Bulb
- 1 November 1973
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 4 (6) , 955-957
- https://doi.org/10.1161/01.str.4.6.955
Abstract
A method of jugular bulb cannulation is discussed which is quick and easy to perform, ensures accurate placement of the catheter tip and causes minimal discomfort to the patient. Advantages of this technique are discussed.Keywords
This publication has 6 references indexed in Scilit:
- Validity of internal jugular blood for study of cerebral blood flow and metabolismJournal of Applied Physiology, 1961
- DYNAMIC ANATOMY OF THE CEREBRAL CIRCULATIONArchives of Neurology & Psychiatry, 1948
- VOLUME FLOW OF BLOOD THROUGH THE HUMAN BRAINArchives of Neurology & Psychiatry, 1947
- BILATERAL INTERNAL JUGULAR BLOODAmerican Journal of Psychiatry, 1945
- THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONSAmerican Journal of Physiology-Legacy Content, 1945
- TECHNIC FOR OBTAINING BLOOD FROM THE INTERNAL JUGULAR VEIN AND INTERNAL CAROTID ARTERYArchives of Neurology & Psychiatry, 1927