Automated reduction and interpretation of
Top Cited Papers
- 1 April 2000
- journal article
- Published by American Chemical Society (ACS)
- Vol. 11 (4) , 320-332
- https://doi.org/10.1016/s1044-0305(99)00157-9
Abstract
Here a fully automated computer algorithm is applied to complex mass spectra of peptides and proteins. This method uses a subtractive peak finding routine to locate possible isotopic clusters in the spectrum, subjecting these to a combination of the previous Fourier transform/ Patterson method for primary charge determination and the method for least-squares fitting to a theoretically derived isotopic abundance distribution for m/z determination of the most abundant isotopic peak, and the statistical reliability of this determination. If a predicted protein sequence is available, each such m/z value is checked for assignment as a sequence fragment. A new signal-to-noise calculation procedure has been devised for accurate determination of baseline and noise width for spectra with high peak density. In 2 h, the program identified 824 isotopic clusters representing 581 mass values in the spectrum of a GluC digest of a 191 kDa protein; this is \s>50% more than the number of mass values found by the extremely tedious operator-applied methodology used previously. The program should be generally applicable to classes of large molecules, including DNA and polymers. Thorough high resolution analysis of spectra by Horn (THRASH) is proposed as the program’s verb.Keywords
This publication has 44 references indexed in Scilit:
- Electron Capture Dissociation of Gaseous Multiply-Charged Proteins Is Favored at Disulfide Bonds and Other Sites of High Hydrogen Atom AffinityJournal of the American Chemical Society, 1999
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Efficient sequence analysis of the six gene products (7‐74 kDA) from the escherichia coli thiamin biosynthetic operon by tandem high‐resolution mass spectrometryProtein Science, 1998
- Double stranded DNA sequencing by tandem mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1997
- The Complete Genome Sequence of Escherichia coli K-12Science, 1997
- Peer Reviewed: Internet-Based Analytical Chemistry Resources: A Model ProjectAnalytical Chemistry, 1996
- Sequence Information from 42−108-mer DNAs (Complete for a 50-mer) by Tandem Mass SpectrometryJournal of the American Chemical Society, 1996
- Ultrahigh Resolution Isotope Distribution CalculationsRapid Communications in Mass Spectrometry, 1996
- High‐resolution tandem mass spectra of 37‐67 kDa proteinsJournal of Mass Spectrometry, 1995
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988