Removal of harmonic artifacts from synchrotron radiation coronary angiograms
- 1 October 1992
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 39 (5) , 1431-1437
- https://doi.org/10.1109/23.173220
Abstract
Intravenous coronary angiograms of human subjects are now available from the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL). The high (4.4-T) magnetic field used under normal operation of the superconducting wiggler magnet on the X-17 beam line yields a high critical energy (18.7 keV) and a large harmonic contamination of the desired X-ray flux at the L-edge of iodine (33.169 keV). The 66- and 99-keV contamination is a factor of 2.29 and 5.32 worse than for the human angiograms taken at the Stanford Synchrotron Radiation Laboratory (SSRL), where a critical energy of 13.0 keV was obtained at beam line IV-2. The increased harmonic contamination produces severe artifacts in the images, especially where the patient's ribs cross the left ventricle and aorta, which are filled with contrast agent. An algorithm has been developed which can remove these artifacts by solving the two simultaneous transcendental equations for the fractional X-ray transmissions through iodine and through water. The parameters are derived from measurements on a Lucite step-wedge phantom. Human angiograms taken at 4.4 T are shown before and after the correction algorithm is applied. These corrected angiograms are compared to uncorrected angiograms taken at 3.0 T.Keywords
This publication has 8 references indexed in Scilit:
- Monochromator harmonic content measurements and calculations at energies above 20 keVReview of Scientific Instruments, 1992
- A kinestatic charge detector for intravenous coronary angiography using synchrotron radiation X-raysIEEE Transactions on Nuclear Science, 1991
- Contrast agent choice for intravenous coronary angiographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990
- Coronary angiography using synchrotron radiation (invited)Review of Scientific Instruments, 1989
- Transvenous coronary angiography in humans using synchrotron radiation.Proceedings of the National Academy of Sciences, 1986
- Veiling Glare Of A Linear Multichannel Si(Li) DetectorOptical Engineering, 1986
- 300-Element Silicon-Lithium Position-Sensitive Imaging Detector for AngiographyIEEE Transactions on Nuclear Science, 1986
- Evaluation of synchrotron X-rays for transvenous coronary angiographyNuclear Instruments and Methods in Physics Research, 1984