Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Top Cited Papers
- 1 April 2000
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 215 (1) , 55-62
- https://doi.org/10.1148/radiology.215.1.r00ap3755
Abstract
To evaluate the imaging performance characteristics of four multidetector-row helical computed tomography (CT) and assess improvement in volume coverage speed over that with single multidetector-row helical CT. The section-sensitivity profile and image noise of a four multidetector-row scanner were measured with phantom scans and compared with predictions from theoretic models. Nominal section thickness ranged from 1.25 to 10.00 mm, beam collimation from 1.25 to 5.00 mm, and table speed from 3.75 to 30.00 mm per rotation. Image artifacts with four and single multidetector-row helical CT were compared in both a phantom study and a subjective rating analysis of clinical images. Compared with single multidetector-row helical CT, the volume coverage speed of four multidetector-row helical CT (range, 3.75-30.00 mm per rotation) is at least twice as fast as that with single multidetector-row helical CT (1.0-10.0 mm per rotation) with fully comparable image quality or, in many cases, three times as fast with diagnostically comparable image quality. Compared with single multidetector-row helical CT, four multidetector-row helical CT provides a two- to threefold improvement in volume coverage speed with comparable diagnostic image quality.Keywords
This publication has 17 references indexed in Scilit:
- Multi‐slice helical CT: Scan and reconstructionMedical Physics, 1999
- Helical CT reconstruction with longitudinal filtrationMedical Physics, 1998
- Algorithm for image reconstruction in multi-slice helical CTMedical Physics, 1998
- CT evaluation of pulmonary embolism: technique and interpretation.American Journal of Roentgenology, 1997
- A general approach to the reconstruction of x‐ray helical computed tomographyMedical Physics, 1996
- Helical CT for the preoperative localization of islet cell tumors of the pancreas: value of arterial and parenchymal phase images.American Journal of Roentgenology, 1995
- Longitudinal resolution in volumetric x-ray computerized tomography-Analytical comparison between conventional and helical computerized tomographyMedical Physics, 1994
- Helical CT image noise-analytical resultsMedical Physics, 1993
- Physical performance characteristics of spiral CT scanningMedical Physics, 1991
- Computed tomography scanning with simultaneous patient translationMedical Physics, 1990