Single‐Lead VDD Pacing System
- 30 June 1990
- journal article
- editorial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 13 (6) , 757-766
- https://doi.org/10.1111/j.1540-8159.1990.tb02102.x
Abstract
A single pass ventricular lead with a dual chamber electrode system, designed for VDD pacing, was implanted in 17 patients (11 men, 6 women, aged 53 to 86 years, mean 74) for symptomatic bradycardia due to second-or third-degree AV block and normal sinus node function. Bipolar atrial electrodes, diagonally displaced along the lead axis and positioned within the right atrial cavity, are used to detect atrial activity that is then differentially processed within the pacemaker. P wave amplitude (amp) derived from a PSA-DAA device at implant was 1.38 +/- 0.28 mV. P wave signal amp derived from telemetered atrial electrograms was 1.29 +/- 0.22 mV at predischarge (n = 17), 1.31 +/- 0.24 mV at 3 months (n = 15), 1.30 +/- 0.24 mV at 6 months (n = 8), 1.51 +/- 0.34 mV at 9 months (n = 4), and 1.35 +/- 0.35 mV at 12 months (n = 2); and the far-field QRS signal measured at predischarge was of negligible voltage (0.17 +/- 0.07 mV). The susceptibility of the atrial sensor system to interference was noted with chest wall stimulation and only at higher sensitivities (0.1 to 0.3 mV) and not with isometric arm exercise. Intact VDD pacing function at rest and during exercise was established using Holter and periodic ECG monitoring. Postoperative complications included one lead displacement and one pocket hematoma. Three patients died postimplant of causes unrelated to pacemaker function. Advantages of the single-lead VDD pacing include: (1) elimination of second atrial sensing lead; (2) superior atrial sensing performance; (3) effective resistance to myopotential and far-field signal interference; and (4) stability of postimplant atrial signal amplitude.Keywords
This publication has 21 references indexed in Scilit:
- Role of left ventricular function and Doppler-derived variables in predicting hemodynamic benefits of rate-responsive pacingThe American Journal of Cardiology, 1988
- Decrease in Canine Endocardial and Epicardial Electrogram Voltages with Exercise: Implications for Pacemaker SensingPacing and Clinical Electrophysiology, 1988
- Clinical and hemodynamic comparison of VVI versus DDD pacing in patients with DDD pacemakersThe American Journal of Cardiology, 1988
- Comparison of Myopotential Interference in Unipolar‐Bipolar Programmable DDD PacemakersPacing and Clinical Electrophysiology, 1987
- Simultaneous right atrial appendage sensing with a target tip, a solid tip and j orthogonal electrodesThe American Journal of Cardiology, 1987
- Physiological Versus Single-Rate Ventricular Pacing: A Double-Blind Cross-Over StudyPacing and Clinical Electrophysiology, 1985
- Myopotential interference with DDD pacemakers: Endocardial electrographic telemetry in the diagnosis of pacemaker-related arrhythmiasThe American Journal of Cardiology, 1984
- Orthogonal Electrogram SensingPacing and Clinical Electrophysiology, 1983
- A comparison of the acute and long-term hemodynamic effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing.Circulation, 1982
- A New Orthogonal Lead for P Synchronous PacingPacing and Clinical Electrophysiology, 1981