Mass determination of megadalton-DNA electrospray ions using charge detection mass spectrometry
- 1 April 1998
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 9 (4) , 305-313
- https://doi.org/10.1016/s1044-0305(97)00290-0
Abstract
Charge detection mass spectrometry (CD-MS) has been used to determine the mass of double-stranded, circular DNA and single-stranded, circular DNA in the range of 2500 to 8000 base pairs (1.5–5.0 MDa). Simultaneous measurement of the charge and velocity of an electrostatically accelerated ion allows a mass determination of the ion, with instrument calibration determined independently of samples. Positive ion mass spectra of electrosprayed commercial DNA samples supplied in tris(hydroxymethyl)ethylenediaminetetraacetic acid buffer, diluted in 50 vol. % acetonitrile, were obtained without cleanup of the sample. A CD mass spectrum constructed from 3000 ion measurements takes 10 min to acquire and yields the DNA molecular mass directly (mass resolution = 6). The data collected represent progress toward a more automatable alternative to sizing of DNA by gel electrophoresis. In addition to the mass spectra, CD-MS generates charge versus mass plots, which provide another means to investigate the creation and fate of large electrospray ions.Keywords
This publication has 20 references indexed in Scilit:
- Molecular weight determination of plasmid DNA using electrospray ionization mass spectrometryNucleic Acids Research, 1996
- Analytical Properties of the Nanoelectrospray Ion SourceAnalytical Chemistry, 1996
- Trapping, Detection, and Mass Determination of Coliphage T4 DNA Ions by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 1995
- Molecular weight determination of megadalton DNA electrospray ions using charge detection time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1995
- Trapping, Detection, and Mass Measurement of Individual Ions in a Fourier Transform Ion Cyclotron Resonance Mass SpectrometerJournal of the American Chemical Society, 1994
- Trapping, detection and reaction of very large single molecular ions by mass spectrometryNature, 1994
- An electrospray‐ionization mass spectrometer with new featuresRapid Communications in Mass Spectrometry, 1990
- Collisional activation and collision-activated dissociation of large multiply charged polypeptides and proteins produced by electrospray ionizationJournal of the American Society for Mass Spectrometry, 1990
- Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometryAnalytical Biochemistry, 1989
- Electrospray interface for liquid chromatographs and mass spectrometersAnalytical Chemistry, 1985