Cell quality of salvaged blood after total knee arthroplasty:Drain blood compared to venous blood in 32 patients
- 1 January 1995
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 66 (4) , 329-333
- https://doi.org/10.3109/17453679508995555
Abstract
We used the ConstaVac® drainage retransfusion system in 32 patients operated on with cemented tricompartmental knee arthroplasty. The mean total postoperative bleeding was 1.1 L of which 0.7 L was retransfused within 8 hours postoperatively. Samples were taken from the venous blood and drain blood at 2 hours and 6-8 hours postoperatively. The drain blood had low counts for leukocytes and thrombocytes as compared to venous blood, and fibrinogen was almost absent. Incubation at room temperature slightly lowered glucose and pH which made the erythrocytes swell. There was a slight hemolysis in the drain blood at 2 hours. At 6-8 hours the shed blood was closer to normal, especially with regard to hemolysis, but there was a further decrease in glucose. Within this time, there was no change in acidity and no further swelling of the erythrocytes. No clinical adverse reactions were observed and we consider the observed cellular and chemical changes to be of little importance. The quality of filtered drain blood within the analyzed time limit is considered acceptable for clinical use.Keywords
This publication has 14 references indexed in Scilit:
- Reinfusion of shed blood after orthopaedic procedures in children and adolescents.Journal of Bone and Joint Surgery, 1993
- Methylmethacrylate Monomer and Fat Content in Shed Blood After Total Joint ArthroplastyClinical Orthopaedics and Related Research, 1993
- Postoperative blood retrieval and transfusion in cementless total knee arthroplastyThe Journal of Arthroplasty, 1992
- Retrofascial pyogenic iliac fossa abscessActa Orthopaedica, 1992
- AutotransfusionActa Orthopaedica, 1992
- Unwashed filtered shed blood collected after knee and hip arthroplasties. A source of autologous red blood cells.Journal of Bone and Joint Surgery, 1991
- Blood loss after total knee replacement. Effects of tourniquet release and continuous passive motion.Journal of Bone and Joint Surgery, 1991
- Complement Activation and Reinfusion of Wound Drainage BloodAnesthesiology, 1990
- Intraoperative autologous transfusion in primary and revision total hip arthroplastyThe Journal of Arthroplasty, 1990
- Decreased deformability of erythrocytes in hyperglycaemic non-inbred ob/ob miceDiabetologia, 1986