Short-Term, Low-Contrast Visual Acuity Reduction Associated with in Vivo Contact Lens Drying
- 1 October 1992
- journal article
- research article
- Published by Wolters Kluwer Health in Optometry and Vision Science
- Vol. 69 (10) , 755-760
- https://doi.org/10.1097/00006324-199210000-00002
Abstract
Hydrogel contact lens surfaces partially desiccate during extended interblink intervals, producing a microscopically rough and irregular surface that scatters light. Such light scattering could reduce retinal image contrast, elevating thresholds for target perception. To test this idea, we measured low (7%)-contrast visual acuity of subjects who wore: (1) hydrogel contact lenses, (2) rigid gas permeable (RGP) lenses, and (3) no contact lenses when the subjects blinked normally and when they suppressed blinking. Acuity thresholds were determined using computer-generated acuity stimuli and a staircase psychophysical procedure. Cessation of blinking resulted in small reductions in low-contrast acuity for subjects wearing RGP lenses (mean loss: 0.1 line) or no lenses (mean loss: 0.3 lines). Subjects wearing hydrogel lenses, however, generally exhibited substantial reduction of acuity (mean loss: 4.1 lines) when blinking was suppressed.Keywords
This publication has 0 references indexed in Scilit: