Measuring the arterial input function with gradient echo sequences
- 16 May 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (6) , 1067-1076
- https://doi.org/10.1002/mrm.10461
Abstract
The measurement of the arterial input function by use of gradient echo sequences was investigated by in vitro and in vivo experiments. First, calibration curves representing the influence of the concentration of Gd‐DTPA on both the phase and the amplitude of the MR signal were measured in human blood by means of a slow‐infusion experiment. The results showed a linear increase in the phase velocity and a quadratic increase in ΔR as a function of the Gd‐DTPA concentration. Next, the resultant calibration curves were incorporated in a partial volume correction algorithm for the arterial input function determination. The algorithm was tested in a phantom experiment and was found to substantially improve the accuracy of the concentration measurement. Finally, the reproducibility of the arterial input function measurement was estimated in 16 patients by considering the input function of the left and the right sides as replicate measurements. This in vivo study showed that the reproducibility of the arterial input function determination using gradient echo sequences is improved by employing a partial volume correction algorithm based on the calibration curve for the contrast agent used. Magn Reson Med 49:1067–1076, 2003.Keywords
This publication has 17 references indexed in Scilit:
- Quantification of Perfusion Using Bolus Tracking Magnetic Resonance Imaging in StrokeStroke, 2002
- On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRIMagnetic Resonance in Medicine, 2001
- Arterial input functions from MR phase imagingMagnetic Resonance in Medicine, 1996
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Mr contrast due to intravascular magnetic susceptibility perturbationsMagnetic Resonance in Medicine, 1995
- Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.Radiology, 1994
- Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3DMagnetic Resonance Imaging, 1994
- Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effectsJournal of Magnetic Resonance Imaging, 1993
- Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental conceptsMagnetic Resonance in Medicine, 1991
- Transport through Red Cell MembranesPublished by Elsevier ,1975