Adequacy of surgeon‐performed ultrasound‐guided thyroid fine‐needle aspiration biopsy
- 1 July 2008
- journal article
- Published by Wiley in Otolaryngology -- Head and Neck Surgery
- Vol. 139 (1) , 27-31
- https://doi.org/10.1016/j.otohns.2008.04.006
Abstract
Objective To determine the diagnostic accuracy of specimens obtained by a surgeon performing office-based ultrasound (US)-guided fine-needle aspiration biopsy (FNAB) of thyroid nodules. Subjects and Methods From 2003 to 2006, a single surgeon performed 447 consecutive office-based US-guided FNABs without on-site cytological specimen evaluation. Adequate specimens had at least six clusters of follicular cells from at least two separate needle passes. Results Non-diagnostic specimens occurred in 16 of 447 (3.6%) nodules, whereas suboptimal specimens occurred in 17 of 447 (3.8%). Adequate samples were obtained in 413 of 447 (92.6%) of specimens. Malignancy was present in 20 of 447 (4.5%) and atypical features were present in 37 of 447 (8.3%). Benign diagnoses were rendered in 357 of 447 (79.9%) of specimens, of which four of 357 (1.1%) represented false-negative results. Conclusion Prior publications recommend that obtaining adequate thyroid cytology specimens requires use of US-guided FNAB and on-site evaluation of cytology adequacy. This study demonstrates that a combination of experienced US guidance, both capillary and aspiration sampling, and three to four needle passes produce comparable results while conserving costs and resources.Keywords
This publication has 14 references indexed in Scilit:
- How important is on‐site adequacy assessment for thyroid FNA? An evaluation of 883 casesDiagnostic Cytopathology, 2007
- Comparison of Palpation-Guided Fine-Needle Aspiration Biopsy to Ultrasound-Guided Fine-Needle Aspiration Biopsy in the Evaluation of Thyroid NodulesThyroid®, 2006
- The value of onsite adequacy assessment of thyroid fine-needle aspirations is a function of operator experienceCancer, 2006
- Intrathyroid Hemorrhage and Acute Upper Airway Obstruction after Fine Needle Aspiration of the Thyroid GlandThe Laryngoscope, 2006
- The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid NodulesThyroid®, 2006
- Ultrasound-Guided Fine-Needle Capillary Biopsy of Thyroid Nodules, Coupled with On-Site Cytologic Review, Improves ResultsThyroid®, 2004
- Cost-Effectiveness of Immediate Specimen Adequacy Assessment of Thyroid Fine-Needle AspirationsAmerican Journal of Clinical Pathology, 2004
- Diagnostic value and cost‐effectiveness of on‐site evaluation of fine‐needle aspiration specimens: Review of 5,688 casesDiagnostic Cytopathology, 2002
- Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid MassesThyroid®, 1998
- Diagnostic Accuracy of Conventional Versus Sonography-Guided Fine-Needle Aspiration Biopsy of Thyroid NodulesThyroid®, 1998