Comparison of imaging geometries for diffuse optical tomography of tissue
- 12 April 1999
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 4 (8) , 270-286
- https://doi.org/10.1364/oe.4.000270
Abstract
Images produced in six different geometries with diffuse optical tomography simulations of tissue have been compared using a finite element-based algorithm with iterative refinement provided by the Newton-Raphson approach. The source-detector arrangements studied include (i) fan-beam tomography, (ii) full reflectance and transmittance tomography, as well as (iii) sub-surface imaging, where each of these three were examined in a circular and a flat slab geometry. The algorithm can provide quantitatively accurate results for all of the tomographic geometries investigated under certain circumstances. For example, quantitatively accurate results occur with sub-surface imaging only when the object to be imaged is fully contained within the diffuse projections. In general the diffuse projections must sample all regions around the target to be characterized in order for the algorithm to recover quantitatively accurate results. Not only is it important to sample the whole space, but maximal angular sampling is required for optimal image reconstruction. Geometries which do not maximize the possible sampling angles cause more noise artifact in the reconstructed images. Preliminary simulations using a mesh of the human brain confirm that optimal images are produced from circularly symmetric source-detector distributions, but that quantitatively accurate images can be reconstructed even with a sub-surface imaging, although spatial resolution is modest.Keywords
This publication has 29 references indexed in Scilit:
- A gradient-based optimisation scheme for optical tomographyOptics Express, 1998
- Frequency‐domain near‐infrared photo diffusion imaging: Initial evaluation in multitarget tissuelike phantomsMedical Physics, 1998
- A fundamental limitation of linearized algorithms for diffuse optical tomographyOptics Express, 1997
- Image reconstruction in optical tomographyPhilosophical Transactions Of The Royal Society B-Biological Sciences, 1997
- Detection and characterization of optical inhomogeneities with diffuse photon density waves: a signal-to-noise analysisApplied Optics, 1997
- Luminescence optical tomography of dense scattering mediaJournal of the Optical Society of America A, 1997
- Tomographic image reconstruction from optical projections in light-diffusing mediaApplied Optics, 1997
- Resolution limits for imaging through turbid media with diffuse lightOptics Letters, 1993
- The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysisPhysics in Medicine & Biology, 1992
- Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical propertiesApplied Optics, 1989