An automated surface plasmon resonance (SPR)-based biosensor system has been used for mapping antibody and receptor-binding regions on the recombinant human granulocyte—macrophage colony-stimulating factor (rhGM-CSF) molecule. A rabbit antimouse IgGi-Fc antibody (RAM.Fc) was coupled to an extended carboxymethylated-hydrogel matrix attached to a gold surface in order to capture an anti-rhGM-CSF monoclonal antibody (MAb) injected over the sensing layer. rhGM-CSF was subsequently injected and allowed to bind to this antibody. Multisite binding assays were then performed, by flowing sequentially other antibodies and peptides over the surface, and the capacity of the latter to interact with the entrapped rhGM-CSF in a multimolecular complex was monitored in real time with SPR. Eleven MAb (all IgG1K), were analyzed: respectively, four antipeptide MAb raised against three distinct epitopes of the cytokine (two clones against residues 14-24, that includes part of the first α-helix toward the N-terminal region; one clone against peptide 30-41, an intrahelical loop; and one clone against residues 79-91, including part of the third α-helix) and seven antiprotein MAbs raised against the entire rhGM-CSF, whose target native epitopes are still undetermined. In addition, the binding capacity to rhGM-CSF of a synthetic peptide, corresponding to residues 238-254 of the extracellular human GM-CSF receptor α-chain, endowed with rhGM-CSF binding activity, was tested. The results from experiments performed with the biosensor were compared with those obtained by a sandwich enzyme-linked immunosorbent assay (ELISA), using the same reagents. The features of the biosensor technology (fully automated, measure in real time, sharpened yes/no response, less background disturbances, no need for washing step or labeling of the reagent) offered several advantages in these studies of MAb immunoreactivity and epitope mapping, giving a much better resolution and enabling more distinct epitopes to be identified over ELISA.Keywords
This publication has 23 references indexed in Scilit:
- Binding of Human GM-CSF to Synthetic Peptides of the Alpha Subunit of Its ReceptorJournal of Receptors and Signal Transduction, 1996
- Principles of biosensing with an extended coupling matrix and surface plasmon resonanceSensors and Actuators B: Chemical, 1993
- Three-dimensional structure of recombinant human granulocyte-macrophage colony-stimulating factorJournal of Molecular Biology, 1992
- Novel Fold and Putative Receptor Binding Site of Granulocyte-Macrophage Colony-Stimulating FactorScience, 1991
- Integrated fluid handling system for biomolecular interaction analysisAnalytical Chemistry, 1991
- Recombinant human granulocyte-macrophage colony-stimulating factor stimulates in vitro mature human neutrophil and eosinophil function, surface receptor expression, and survival.Journal of Clinical Investigation, 1986
- Induction of Macrophage Tumoricidal Activity by Granulocyte-Macrophage Colony-Stimulating FactorScience, 1986
- Human GM-CSF: Molecular Cloning of the Complementary DNA and Purification of the Natural and Recombinant ProteinsScience, 1985
- Structural and functional influence of enzyme-antibody interactions: effects of eight different monoclonal antibodies on the enzymatic activity of Escherichia coli tryptophan synthaseBiochemistry, 1984
- Monoclonal antibodies against mouse nerve growth factor produced by somatic cell hybridsJournal of Neuroscience Research, 1981