Femoral prosthesis implantation induces changes in bone stress that depend on the extent of porous coating
- 1 July 1994
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 12 (4) , 553-563
- https://doi.org/10.1002/jor.1100120412
Abstract
The objective of this study was to evaluate the effect of implantation of porous‐coated anatomic medullary fitting prostheses on stress in the proximal femur. Three‐dimensional finite element models of a cadaveric femur before and after implantation were used to evaluate the resulting changes in stress in the bone. Models of the femur were generated automatically from computed tomographic scan data with use of an innovative mesh‐generation technique. The models were analyzed for three levels of porous coating (proximal, 5/8, and full), with the assumption of ideal ingrowth (perfect bonding) over porous areas and a frictionless, tension‐free surface on smooth areas. All models were loaded and restrained to represent conditions of normal gait. The stresses predicted in the implanted femur are consistent with clinical observations of proximal cortical atrophy (normal stress reduced to 6‐9% of normal at the calcar and 50–55% at mid‐prosthesis) and of hypertrophy at the porous coating junctions (normal stress at the 5/8‐coating junction, 123% of stress proximal to the junction) and hypertrophy near the distal tip of the prosthesis (anterior and posterior normal stresses 200–800% of normal). The fully coated prosthesis induced stresses in the bone near the tip of the prosthesis that were most like stresses in the normal femur (medial and lateral normal stress 105 and 102% of the stress in the normal femur). Below the collar, the normal stress associated with the proximally coated prosthesis was 6% greater than that produced with the other two levels of coating but still was only 2% of normal. The 5/8‐coated prosthesis appeared to combine the worst features of the fully coated and proximally coated prostheses–greater stress‐shielding at the calcar and higher stress near the tip of the prosthesis.Keywords
This publication has 35 references indexed in Scilit:
- Validation of an automated method of three-dimensional finite element modelling of boneJournal of Biomedical Engineering, 1993
- Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplastyJournal of Orthopaedic Research, 1992
- Automated three-dimensional finite element modelling of bone: a new methodJournal of Biomedical Engineering, 1990
- Effect of interface conditions on the behaviour of a Freeman hip endoprosthesisJournal of Biomedical Engineering, 1989
- The Effect of Stem Fit on Bone Hypertrophy and Pain Relief in Cementless Total Hip ArthroplastyPublished by Wolters Kluwer Health ,1989
- Macroscopic and Microscopic Evidence of Prosthetic Fixation with Porous-Coated MaterialsClinical Orthopaedics and Related Research, 1988
- A nonlinear finite element analysis of interface conditions in porous coated hip endoprosthesesJournal of Biomechanics, 1988
- Trabecular bone density and loading history: Regulation of connective tissue biology by mechanical energyJournal of Biomechanics, 1987
- Adaptive bone-remodeling theory applied to prosthetic-design analysisJournal of Biomechanics, 1987
- The effect of proximally and fully porous‐coated canine hip stem design on bone modelingJournal of Orthopaedic Research, 1987