A basic study on lesion detectability for hot spot imaging of positron emitters with dedicated PET and positron coincidence gamma camera
- 1 June 2001
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 15 (3) , 301-306
- https://doi.org/10.1007/bf02987851
Abstract
The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0 This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor.Keywords
This publication has 10 references indexed in Scilit:
- Tumour detectability in 2-dimensional and 3-dimensional positron emission tomography using the SET-2400W: a phantom studyNuclear Medicine Communications, 2001
- PET imaging using dual-headed gamma camerasNuclear Medicine Communications, 1999
- Oncologic diagnosis with 2-[fluorine-18]fluoro-2-deoxy-D-glucose imaging: dual-head coincidence gamma camera versus positron emission tomographic scanner.Radiology, 1998
- PET and [18F]-FDG in oncology: A clinical updateNuclear Medicine and Biology, 1996
- Positron emission tomography: a financial and operational analysis.American Journal of Roentgenology, 1994
- Technology for FDG SPECT with a relatively inexpensive gamma camera. Work in progress.Radiology, 1994
- Performance characteristics of a 511-keV collimator for imaging positron emitters with a standard gamma-cameraEuropean Journal of Nuclear Medicine and Molecular Imaging, 1992
- National Cancer Institute Workshop StatementArchives of internal medicine (1960), 1990
- National Cancer Institute Workshop statement. Advances in clinical imaging using positron emission tomography, September 14-16, 1988. The Workshop PanelArchives of internal medicine (1960), 1990
- Recurrence of colorectal tumors: PET evaluation.Radiology, 1989