Intraoperative ultrasound for guidance and tissue shift correction in image‐guided neurosurgery
Top Cited Papers
- 5 April 2000
- journal article
- case report
- Published by Wiley in Medical Physics
- Vol. 27 (4) , 787-800
- https://doi.org/10.1118/1.598942
Abstract
We present a surgical guidance system that incorporates pre‐operative image information (e.g., MRI) with intraoperative ultrasound (US) imaging to detect and correct for brain tissue deformation during image‐guided neurosurgery (IGNS). Many interactive IGNS implementations employ pre‐operative images as a guide to the surgeons throughout the procedure. However, when a craniotomy is involved, tissue movement during a procedure can be a significant source of error in these systems. By incorporating intraoperative US imaging, the target volume can be scanned at any time, and two‐dimensional US images may be compared directly to the corresponding slice from the pre‐operative image. Homologous points may be mapped from the intraoperative to the pre‐operative image space with an accuracy of better than 2 mm, enabling the surgeon to use this information to assess the accuracy of the guidance system along with the progress of the procedure (e.g., extent of lesion removal) at any time during the operation. Anatomical features may be identified on both the pre‐operative and intraoperative images and used to generate a deformation map, which can be used to warp the pre‐operative image to match the intraoperative US image. System validation is achieved using a deformable multi‐modality imaging phantom, and preliminary clinical results are presented.Keywords
This publication has 47 references indexed in Scilit:
- Computer Navigational Microscope for Minimally Invasive Neurosurgerymin - Minimally Invasive Neurosurgery, 1997
- Preliminary Clinical Experience with Intraoperative Stereotactic Ultrasound ImagingStereotactic and Functional Neurosurgery, 1997
- Application accuracy study of a semipermanent fiducial system for frameless stereotaxisComputer Aided Surgery, 1997
- Technical Note. Effect of Geometrical Distortion Correction in MR on Image Registration AccuracyJournal of Computer Assisted Tomography, 1996
- Ultrasound-guided neurosurgery: a feasibility study in the 3-30 MHz frequency rangeBritish Journal Of Neurosurgery, 1996
- Validation of transcranial Doppler ultrasound with a stereotactic neurosurgical techniqueJournal of Neurosurgery, 1995
- Use of the Horsley-Clarke Stereotactic Frame in HumansStereotactic and Functional Neurosurgery, 1995
- Intraoperative ultrasound (US) imaging. Comparison of pathomorphological findings in US and CTActa Neurochirurgica, 1990
- Practical application of intraoperative ultrasound imagingActa Neurochirurgica, 1990
- The first human stereotaxic apparatusJournal of Neurosurgery, 1983