Development of a sensitive and specific liquid chromatography/mass spectrometry method for the determination of tenofovir in human plasma
- 1 June 2007
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (13) , 2087-2094
- https://doi.org/10.1002/rcm.3056
Abstract
A sensitive and specific method for the quantitation of tenofovir (TFV) in human plasma by liquid chromatography/electrospray ionization mass spectrometry was developed and validated. Plasma samples were prepared by solid-phase extraction performed on Waters Oasis cation-exchange cartridges (30 mg). Chromatographic separation was performed isocratically on a reversed-phase Waters Atlantis dC18 column (2.0 × 100 mm, 3 µm). The mobile phase consisted of a hydroxylamine/acetic acid buffer (pH 6.75) and methanol (93:7, v/v). The acquisition was performed in selected ion monitoring mode for the protonated molecular ions [M+H]+ of m/z 288.2 for TFV and 212.2 for the internal standard, zalcitibine. The method was fully validated to determine its specificity, recovery, linearity and sensitivity, accuracy and precision. The analytical range was set at 1–750 ng/mL using a 200 µL plasma sample, with a mean coefficient of determination (r2) of 0.9969. The mean accuracies for the calibration standards ranged from −5.0 to 4.3%, while the precisions were within 1.2 and 6.4%. Intra-assay and inter-assay mean accuracies for three quality control concentrations (2, 60, and 600 ng/mL) ranged from −6.1 to 10.7%, while the precisions were within 1.3 and 9.1%. TFV was shown to be stable under normal storage and assay conditions; no degradation was seen when stored at −20°C or −80°C for up to 6 months, and after 16 h at room temperature in the injection matrix. The present method provides an accurate, precise, and sensitive tool for TFV quantitation and was successfully applied to an external proficiency-testing program and pharmacokinetic analysis. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 12 references indexed in Scilit:
- Liquid chromatography–tandem mass spectrometric determination of tenofovir-diphosphate in human peripheral blood mononuclear cellsJournal of Chromatography B, 2006
- Sensitive assay for determining plasma tenofovir concentrations by LC/MS/MSJournal of Chromatography B, 2006
- Simultaneous analysis of several antiretroviral nucleosides in rat-plasma by high-performance liquid chromatography with UV using acetic acid/hydroxylamine buffer: Test of this new volatile medium-pH for HPLC–ESI-MS/MSJournal of Chromatography B, 2005
- Quality Assurance Program for Clinical Measurement of Antiretrovirals: AIDS Clinical Trials Group Proficiency Testing Program for Pediatric and Adult Pharmacology LaboratoriesAntimicrobial Agents and Chemotherapy, 2004
- Tenofovir Disoproxil FumarateClinical Pharmacokinetics, 2004
- A study of ion suppression effects in electrospray ionization from mobile phase additives and solid‐phase extractsRapid Communications in Mass Spectrometry, 2003
- Liquid chromatographic assay for the antiviral nucleotide analogue tenofovir in plasma using derivatization with chloroacetaldehydeJournal of Chromatography B, 2003
- Sensitive determination of tenofovir in human plasma samples using reversed-phase liquid chromatographyJournal of Chromatography B, 2003
- Determination of tenofovir in human plasma by high-performance liquid chromatography with spectrofluorimetric detectionJournal of Chromatography B, 2002
- LC/MS DETERMINATION OF THE INTRACELLULAR CONCENTRATION OF TWO NOVEL ARYL PHOSPHORAMIDATE PRODRUGS OF PMPA AND THEIR METABOLITES IN DOG PBMCNucleosides, Nucleotides and Nucleic Acids, 2001