PERMEABILITY OF BLOOD-OCULAR BARRIERS OF NEONATAL AND ADULT CATS TO FLUORESCEIN-LABELED DEXTRANS OF SELECTED MOLECULAR SIZES
- 1 January 1981
- journal article
- research article
- Vol. 21 (2) , 282-290
Abstract
The permeability of the ocular blood vessels and neuroepithelial layers (the blood-ocular barriers) to fluorescein-labeled dextrans of selected molecular sizes was evaluated in neonatal and adult cats by fluorescence microscopy. The iris and ciliary process vessels were permeable to molecules as large as 85.ANG. effective diffusion radius (EDR). In the kitten, the choriocapillaris was permeable to molecules as large as 58.ANG. EDR, and in the adult to molecules only as large as 32.ANG. EDR. The retinal vessels and the retinal pigment epithelium were impermeable to all markers. The role of the cat''s iris vessel in aqueous humor formation appears dissimilar to that of other species in that molecules larger than serum proteins traverse the walls of the iris capillaries.This publication has 4 references indexed in Scilit:
- PERMEABILITY OF BLOOD-OCULAR BARRIERS OF NEONATAL AND ADULT CAT TO SODIUM FLUORESCEIN1980
- Selected molecular weight dextrans for in vivo permeability studies of rat retinal vascular diseaseExperimental Eye Research, 1977
- Permeability of fluorescein-labelled dextrans in fundus fluorescein angiography of rats and birdsExperimental Eye Research, 1977
- The use of fluorescein-labelled dextrans in investigation of aqueous humour outflow in the rabbitExperimental Eye Research, 1976