Clearance calculations in hemodialysis: Application to blood, plasma, and dialysate measurements for ethambutol
- 1 February 1980
- journal article
- research article
- Published by Springer Nature in Journal of Pharmacokinetics and Biopharmaceutics
- Vol. 8 (1) , 69-81
- https://doi.org/10.1007/bf01059449
Abstract
With the increasing use of artificial kidneys, numerous reports have appeared describing the pharmacokinetics of administered drugs in dialysis patients. Unfortunately, different investigators use different measures of dialysis clearance in reporting their results. Few studies have appeared in which actual measurements have been made in blood and dialysate as well as in plasma to experimentally show the variability of individual measurements and to demonstrate the inaccuracy of certain clearance measurements. We do so here, using the drug ethambutol. The effect of the artificial kidney on the removal of ethambutol was investigated in four uremic patients undergoing chronic hemodialysis. Ethambutol was administered by i.v. infusion over 30 min. Hemodialysis started at the end of drug infusion. Blood, plasma, and dialysate samples were collected periodically over 3 hr and analyzed for ethambutol content. Dialysis clearance was calculated by arterialvenous difference and by simultaneous dialysate measurement. The extraction efficiency of the hollow fiber dialyzers ranged from 36.2% to 43.8% in terms of blood and from 38.0% to 45.4% in terms of plasma. The mean clearance values due to dialysis were 108.08 and 88.1 ml/min measured with plasma and blood as body fluids of reference, respectively. Dialysis clearance calculated by dialysate measurement had a mean of 85.9 ml/min expressed as plasma and 74.7 ml/min expressed as blood. This study demonstrates that dialysis clearance when calculated using A-V difference and plasma flow is generally underestimated, particularly for a drug which extensively partitions into red blood cells. Ethambutol had a partition coefficient (blood/plasma) of greater than 1 in all four patients. The β phase exhibited a mean half-life of approximately 2 hr on dialysis in comparison to off dialysis half-lives of 7 hror longer in renal failure. Although ethambutol exhibits a markedly reduced half-life of the drug during hemodialysis, its recovery in the dialysis fluid during a 3-hr dialysis period constitutes only a small fraction of the dose administered.This publication has 14 references indexed in Scilit:
- Disposition kinetics of ethambutol in manJournal of Pharmacokinetics and Biopharmaceutics, 1980
- Micro and Macro GLC Determination of Ethambutol in Biological FluidsJournal of Pharmaceutical Sciences, 1978
- Ethambutol HydrochlorideAnalytical Profiles of Drug Substances, 1978
- Kinetics of oral ethambutol in the normal subjectClinical Pharmacology & Therapeutics, 1977
- Drug Kinetics and Artificial Kidneys1Clinical Pharmacokinetics, 1977
- Artificial kidneys and clearance calculationsClinical Pharmacology & Therapeutics, 1976
- Gas-liquid chromatographic determination of ethambutol in plasma and urine of man and monkeyJournal of Chromatography A, 1976
- [Comparison between renal clearances with inulin and para-aminohippuric acid and blood concentrations of ethambutol].1972
- Zur Pharmakokinetik von Ethambutol bei Gesunden und Patienten mit terminaler NiereninsuffizienzDeutsche Medizinische Wochenschrift (1946), 1971
- METABOLIC AND SPECIAL STUDIES OF ETHAMBUTOL IN NORMAL VOLUNTEERS AND TUBERCULOUS PATIENTSAnnals of the New York Academy of Sciences, 1966