Absorbed fractions in a voxel-based phantom calculated with theMCNP-4Bcode
- 11 July 2000
- journal article
- Published by Wiley in Medical Physics
- Vol. 27 (7) , 1555-1562
- https://doi.org/10.1118/1.599021
Abstract
A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. MCNP-4B absorbed fractions for photons in the mathematical phantom of Snyder et al. agreed well with reference values. Results obtained through radiation transport simulation in the voxel-based phantom, in general, agreed well with reference values. Considerable discrepancies, however, were found in some cases due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom, which is not considered in the mathematical phantom.Keywords
This publication has 4 references indexed in Scilit:
- MABDOSE. I: Characterization of a general purpose dose estimation codeMedical Physics, 1999
- Treatment planning for radio-immunotherapyPhysics in Medicine & Biology, 1996
- A Monte Carlo approach to patient-specific dosimetryMedical Physics, 1996
- Radiation dosimetry for radioimmunotherapy. An overview of current capabilities and limitationsCancer, 1994