Slow Rhythmic Oscillations of Blood Pressure, Intracranial Pressure, Microcirculation, and Cerebral Oxygenation
- 1 December 1996
- journal article
- Published by Wolters Kluwer Health in Stroke
- Vol. 27 (12) , 2236-2243
- https://doi.org/10.1161/01.str.27.12.2236
Abstract
Various biological signals show nonpulsatile, slow rhythmic oscillations. These include arterial blood pressure (aBP), blood flow velocity in cerebral arteries, intracranial pressure (ICP), cerebral microflow, and cerebral tissue PO2. Generation and interrelations between these rhythmic fluctuations remained unclear. The aim of this study was to analyze whether stable dynamic interrelations in the low-frequency range exist between these different variables, and if they do, to analyze their exact time delay. In a clinical study, 16 comatose patients with either higher-grade subarachnoid hemorrhage or severe traumatic brain injury were examined. A multimodal digital data acquisition system was used to simultaneously monitor aBP, flow velocity in the middle cerebral artery (FVMCA), ICP, cerebral microflow, and oxygen saturation in the jugular bulb (SjO2). Cross-correlation as a means to analyze time delay and correlation between two periodic signals was applied to a time series of 30 minutes' duration divided into four segments of 2048 data points (approximately 436 seconds) each. This resulted in four cross-correlations for each 30-minute time series. If the four cross-correlations were consistent and reproducible, averaging of the original cross-correlations was performed, resulting in a representative time delay and correlation for the complete 30-minute interval. Reproducible cross-correlations and stable dynamic interrelations were found between aBP, FVMCA, ICP, and SjO2. The mean time delay between aBP and ICP was 6.89 +/- 1.90 seconds, with a negative correlation in 81%. A mean time delay of 1.50 +/- 1.29 seconds (median, 0.85 seconds) was found between FVMCA and ICP, with a positive correlation in 94%. The mean delay between ICP and SjO2 was 9.47 +/- 2.21 seconds, with a positive correlation in 77%. Mean values of aBP and ICP did not influence the time delay and dynamic interrelation between the different parameters. These results strongly support Rosner's theory that ICP B-waves are the autoregulatory response of spontaneous fluctuations of cerebral perfusion pressure. There is casuistic evidence that failure of autoregulation significantly modifies time delay and the correlation between aBP and ICP.Keywords
This publication has 33 references indexed in Scilit:
- An Experimental Study of Cerebrovascular Resistance, Pressure Transmission, and Craniospinal ComplianceNeurosurgery, 1993
- Rapid Autoregulation of Cerebral Blood Flow: A Laser-Doppler Flowmetry StudyJournal of Cerebral Blood Flow & Metabolism, 1992
- The relationship of blood flow velocity fluctuations to intracranial pressure B wavesJournal of Neurosurgery, 1992
- Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke ModelJournal of Cerebral Blood Flow & Metabolism, 1989
- Low-Frequency Oscillations of Cortical Oxidative Metabolism in Waking and SleepJournal of Cerebral Blood Flow & Metabolism, 1988
- Origin and evolution of plateau wavesJournal of Neurosurgery, 1984
- Cerebrospinal Fluid Pulse Wave Form Analysis during Hypercapnia and HypoxiaNeurosurgery, 1981
- Influences of Phasic Changes in Systemic Blood Pressure on Intracranial PressureEuropean Neurology, 1978
- Body position and cerebrospinal fluid pressureJournal of Neurosurgery, 1976
- Cerebral circulation time with ruptured intracranial aneurysmsJournal of Neurosurgery, 1974