Frontal Plane Studies of Homogeneous Torso Models
- 1 May 1954
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 9 (5) , 724-740
- https://doi.org/10.1161/01.cir.9.5.724
Abstract
The accuracy of currently used vector methods of analysis of frontal-plane electrocardiograms and the behavior of the Wilson central-terminal voltage are investigated experimentally by means of an accurate unipolar voltage technic, using human torso models filled with a homogeneous conducting fluid in which is immersed a heart dipole. The errors entailed in the determination of the manifest heart vector from torso surface voltages by means of Einthoven's vector projection methods are found to be very sizable and strongly dependent upon the position of the heart dipole which is placed at various points within the heart volume in this investigation. Einthoven's angle α is found to depart from the actual heart-vector angle by –7 degrees to +41 degrees, at the instant when the manifest heart vector is a maximum, and the amplitude and shape of frontal-plane vector loops and limb leads are found to be considerably distorted, in many cases, as compared with the actual heart-dipole behavior. The Wilson central-terminal voltage is found to depart from its ideal value of zero by approximately 15 to 40 per cent of the maximum value of the manifest heart vector as seen in the frontal plane, in typical cases, and by more than 200 per cent in extreme cases. It is shown that the component of the dipole perpendicular to the frontal plane is not negligible in influencing the limb-electrode potentials. The results are found to be consistent within 10 per cent or better for a male and female torso differing widely in proportions and contour, except for an increase in the female torso voltages arising from its smaller physical dimensions. The results are presented principally in terms of the QRS complex, but the geometric triangle representation is given as are numerical coefficients which describe torso surface voltages.Keywords
This publication has 15 references indexed in Scilit:
- A reference potential for unipolar electrocardiographic measurements on modelsAmerican Heart Journal, 1953
- The elements of electrocardiographic theoryTransactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics, 1953
- A model which demonstrates the quantitative relationship between the electromotive forces of the heart and the extremity leadsAmerican Heart Journal, 1953
- Graphic Representation of Electrocardiographic Leads by Means of Fluid MappersCirculation, 1952
- Experimental studies on the validity of the central terminal of Wilson as an indifferent reference pointAmerican Heart Journal, 1949
- HEART-VECTOR AND LEADS.: Part III geometrical representationHeart, 1948
- On Einthoven's triangle, the theory of unipolar electrocardiographic leads, and the interpretation of the precordial electrocardiogramAmerican Heart Journal, 1946
- THE EFFECT OF AN INJURED AREA ON THE ELECTRICAL FIELD OF THE HEART BASED ON EXPERIMENTS WITH MODELSAmerican Journal of Physiology-Legacy Content, 1942
- Electrocardiograms that represent the potential variations of a single electrodeAmerican Heart Journal, 1934
- Über die Richtung und die manifeste Grösse der Potentialschwankungen im menschlichen Herzen und über den Einfluss der Herzlage auf die Form des ElektrokardiogrammsPflügers Archiv - European Journal of Physiology, 1913