Respiratory reordered UNFOLD perfusion imaging
- 22 October 2004
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 20 (5) , 817-825
- https://doi.org/10.1002/jmri.20183
Abstract
Purpose To propose a respiratory reordered UNFOLD (RR‐UNFOLD) imaging sequence to significantly reduce the amount of k‐space data required for first‐pass MR myocardial perfusion imaging. Materials and Methods Rapid acquisition of high‐resolution imaging data is essential to detailed quantitative analysis of first‐pass myocardial perfusion. Existing MR sequences have explored the full capacity of the imaging hardware to reduce the acquisition window within each cardiac cycle while maintaining the desired spatial resolution. Further improvement in perfusion imaging will require a more efficient use of the information content of the k‐space data. The method uses prospective diaphragmatic navigator echoes to ensure that temporal filtering of UNFOLD is carried out on a series of images that are spatially registered. An adaptive real‐time rebinning algorithm is developed for the creation of static image subseries related to different levels of respiratory motion. Issues concerning the temporal smoothing of tracer kinetic signals are discussed, and a solution based on oversampling of the central k‐space is provided. The method is assessed in 10 normal subjects without the administration of contrast agent, and further validated by administration of Gd‐DTPA in 10 patients at rest. Results The results of this study show that RR‐UNFOLD significantly extends the applicability of UNFOLD to perfusion imaging, which yields a 40% reduction in image artifact when the same amount of k‐space information is used. Conclusion The scan efficiency achieved can be used in combination with MR hardware improvements for extending the three‐dimensional spatial coverage and shortening the data acquisition window to provide detailed information on regional myocardial perfusion abnormalities. J. Magn. Reson. Imaging 2004;20:817–825.Keywords
This publication has 21 references indexed in Scilit:
- Accurate assessment of the arterial input function during high‐dose myocardial perfusion cardiovascular magnetic resonanceJournal of Magnetic Resonance Imaging, 2004
- Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studiesMagnetic Resonance in Medicine, 2003
- Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISPJournal of Magnetic Resonance Imaging, 2002
- Prospective adaptive navigator correction for breath‐hold MR coronary angiographyMagnetic Resonance in Medicine, 1997
- Normal myocardial perfwsion assessed with multishot echo‐planar imagingMagnetic Resonance in Medicine, 1997
- Myocardial perfusion modeling using MRIMagnetic Resonance in Medicine, 1996
- Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparationMagnetic Resonance in Medicine, 1995
- Block Regional Interpolation Scheme for k‐Space (BRISK): A Rapid Cardiac Imaging TechniqueMagnetic Resonance in Medicine, 1995
- Contrast‐enhanced first pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemiaMagnetic Resonance in Medicine, 1993
- First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery diseaseJournal of the American College of Cardiology, 1991