Flexion Failure of Posterior Cervical Lateral Mass Screws
- 15 February 1996
- journal article
- cervical spine
- Published by Wolters Kluwer Health in Spine
- Vol. 21 (4) , 462-468
- https://doi.org/10.1097/00007632-199602150-00010
Abstract
Study Design The strength of posterior cervical lateral mass fixation was evaluated in a cadaver model for two techniques of screw insertion. Objective To compare the flexion failure strengths of posterior cervical plate fixation for two techniques of screw placement at the superior and inferior screw hole positions, and to evaluate the effect of bone mineral density on fixation strength. Summary of Background Data Biomechanical analyses of various screw insertion techniques for posterior cervical lateral mass fixation have never evaluated the effect of screw position along the plate. Methods Individual C3-C6 segments of 24 human cadaveric cervical spines were used. The spinous process and lamina were removed to simulate a postlaminectomy situation. Vertebral body bone mineral density for each specimen was determined by dual-energy radiograph absorption scanning. In each lateral mass, a bicortical 3.5-mm screw was placed using either the Magerl or Roy-Camille insertion technique through an end hole of a titanium bone plate. For “superior” screws, the plate was directed caudally; for “inferior” screws, the plate was directed cranially. Screw violation of the surrounding facet joints was noted. An increasing flexion moment was applied by loading the plate 4 cm from the screw head at a rate of 10 cm/min using a servohydraulic testing machine until screw failure. Results For the superior screw hole position, the Magerl screw sustained a significantly higher average moment to failure (190.2 Ncm) than the Roy-Camille screw (138.7 Ncm; P < 0.05). For the inferior screw hole position, there was no significant difference in flexion failure strength between the two techniques (Magerl screws, 287.7 Ncm; Roy-Camille screws, 308.2 Ncm). For each insertion technique, inferior screws were nearly twice as strong as superior screws (P < 0.01). Violation of the inferior articular process occurred with 53% of Roy-Camille screws and with none of the Magerl screws. Lateral mass fracture on screw insertion occurred with 6% of the Roy-Camille screws and with 7% of the Magerl screws. Significant correlation between screw path length and load to failure was found only at the superior screw hole position. Correlation with vertebral body bone mineral density was significant at both positions. Conclusions The Magerl technique has advantages over the Roy-Camille technique for placing the end screws when performing posterior cervical lateral mass plate fixation, providing greater strength superiorly and not violating unfused facet joints inferiorly. Evaluation of bone mineral density by dual-energy radiographic absorption scanning is predictive of failure strength for both test modes.Keywords
This publication has 19 references indexed in Scilit:
- Posterior plates in the management of cervical instability: long-term results in 44 patientsJournal of Neurosurgery, 1994
- Pullout Strength Comparison of Two Methods of Orienting Screw Insertion in the Lateral Masses of the Bovine Cervical SpinePublished by Wolters Kluwer Health ,1992
- Anatomic Comparison of the Roy-Camille and Magerl Techniques for Screw Placement in the Lower Cervical SpineSpine, 1991
- Anatomic Considerations for Plate-Screw Fixation of the Cervical SpineSpine, 1991
- Posterior Cervical Arthrodesis with AO Reconstruction Plates and Bone GraftSpine, 1991
- Anatomic Considerations in Posterior Plating of the Cervical SpineJournal of Orthopaedic Trauma, 1991
- Influence of Bone Mineral Density on the Fixation of Thoracolumbar Implants A Comparative Study of Transpedicular Screws, Laminar Hooks, and Spinous Process WiresSpine, 1990
- Biomechanical Evaluation of Cervical Spinal Stabilization Methods in a Human Cadaveric ModelSpine, 1989
- Internal Fixation of the Unstable Cervical Spine Using Posterior Roy-Camille PlatesJournal of Orthopaedic Trauma, 1989
- Posterior Plating of the Cervical SpineSpine, 1988