Geometric distortion correction of high‐resolution 3 T diffusion tensor brain images
Open Access
- 26 September 2005
- journal article
- clinical trial
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (5) , 1163-1171
- https://doi.org/10.1002/mrm.20651
Abstract
Diffusion‐weighted images based on echo planar sequences suffer from distortions due to field inhomogeneities from susceptibility differences as well as from eddy currents arising from diffusion gradients. In this paper, a novel approach using nonlinear warping based on optic flow to correct distortions of baseline and diffusion weighted echo planar images (EPI) acquired at 3 T is presented. The distortion correction was estimated by warping the echo planar images to the anatomically correct T2‐weighted fast spin echo images (T2‐FSE). A global histogram intensity matching of the T2‐FSE precedes the base line EPI image distortion correction. A local intensity‐matching algorithm was used to transform labeled T2‐FSE regions to match intensities of diffusion‐weighted EPI images prior to distortion correction of these images. Evaluation was performed using three methods: (i) visual comparison of overlaid contours, (ii) a global mutual information index, and (iii) a local distance measure between homologous points. Visual assessment and the global index demonstrated a decrease in geometrical distortion and the distance measure showed that distortions are reduced to a subvoxel level. In conclusion, the warping algorithm is effective in reducing geometric distortions, enabling generation of anatomically correct diffusion tensor images at 3 T. Magn Reson Med, 2005.Keywords
This publication has 22 references indexed in Scilit:
- Deviations from the diffusion tensor model as revealed by contour plot visualization using high angular resolution diffusion-weighted imaging (HARDI)Magnetic Resonance Materials in Physics, Biology and Medicine, 2003
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Image Distortion Correction in fMRI: A Quantitative EvaluationNeuroImage, 2002
- Diffusion tensor imaging: Concepts and applicationsJournal of Magnetic Resonance Imaging, 2001
- Three-dimensional multimodal brain warping using the Demons algorithm and adaptive intensity correctionsIEEE Transactions on Medical Imaging, 2001
- Unwarping of unidirectionally distorted EPI imagesIEEE Transactions on Medical Imaging, 2000
- Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion modelIEEE Transactions on Medical Imaging, 2000
- On standardizing the MR image intensity scaleMagnetic Resonance in Medicine, 1999
- Correction for geometric distortion in echo planar images from B0 field variationsMagnetic Resonance in Medicine, 1995
- A technique for accurate magnetic resonance imaging in the presence of field inhomogeneitiesIEEE Transactions on Medical Imaging, 1992