Accuracy and Reliability of Remote Retinopathy of Prematurity Diagnosis
- 1 March 2006
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 124 (3) , 322-327
- https://doi.org/10.1001/archopht.124.3.322
Abstract
Objective To determine the accuracy and reliability of retinopathy of prematurity (ROP) diagnosis using remote review of digital images by 3 masked ophthalmologist readers. Methods An atlas was compiled of 410 retinal photographs from 163 eyes of 64 low-birth-weight infants taken using a wide-angle digital fundus camera. All the images were independently reviewed by 3 readers, and the diagnosis in each eye was classified into 1 of 4 ordinal categories: no ROP, mild ROP, type 2 prethreshold ROP, or ROP requiring treatment. Findings were compared with a reference standard of dilated indirect ophthalmoscopy with scleral depression performed by an experienced pediatric ophthalmologist. Results Sensitivities/specificities of the diagnosis of any ROP were 0.845/0.910 for the first reader, 0.816/0.955 for the second reader, and 0.864/0.493 for the third reader. Sensitivities/specificities of the diagnosis of ROP requiring treatment were 0.850/0.960 for the first reader, 0.850/0.973 for the second reader, and 0.900/0.953 for the third reader. When ROP was classified into ordinal categories, the overall weighted κ for interreader reliability was 0.743. Intrareader reliability for detection of low-risk prethreshold ROP or worse was 100% for all readers. Conclusion The accuracy, interreader reliability, and intrareader reliability of remote diagnosis of clinically relevant ROP based on digital imaging are substantial.Keywords
This publication has 10 references indexed in Scilit:
- SINGLE-FIELD FUNDUS PHOTOGRAPHY FOR DIABETIC RETINOPATHY SCREENING: A REPORT BY THE AMERICAN ACADEMY OF OPHTHALMOLOGYEvidence-Based Eye Care, 2004
- Telephotoscreening to detect retinopathy of prematurity: Preliminary study of the optimum time to employ digital fundus camera imaging to detect ROPJournal of American Association for Pediatric Ophthalmology and Strabismus, 2002
- Screening Examination of Premature Infants for Retinopathy of PrematurityPublished by American Academy of Pediatrics (AAP) ,2001
- Systematic review of studies of patient satisfaction with telemedicineBMJ, 2000
- Telemedicine: A New Health Care Delivery SystemAnnual Review of Public Health, 2000
- A review of telemedicine cost-effectiveness studiesJournal of Telemedicine and Telecare, 2000
- Telemedical evaluation and management of retinopathy of prematurity using a fiberoptic digital fundus cameraOphthalmology, 2000
- Systemic effects of screening for retinopathy of prematurity.British Journal of Ophthalmology, 1996
- Screening for Diabetic Retinopathy: The wide-angle retinal cameraDiabetes Care, 1993
- Photographic Grading in the Retinopathy of Prematurity Cryotherapy TrialArchives of Ophthalmology (1950), 1990