Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device
- 23 January 2003
- journal article
- Published by Wiley in Medical Physics
- Vol. 31 (2) , 285-295
- https://doi.org/10.1118/1.1637969
Abstract
The purpose of this study was to investigate the dose-response characteristics, including ghosting effects, of an amorphous silicon-based electronic portal imaging device (a-Si EPID) under clinical conditions. EPID measurements were performed using one prototype and two commercial a-Si detectors on two linear accelerators: one with 4 and 6 MV and the other with 8 and 18 MV x-ray beams. First, the EPID signal and ionization chamber measurements in a mini-phantom were compared to determine the amount of buildup required for EPID dosimetry. Subsequently, EPID signal characteristics were studied as a function of dose per pulse, pulse repetition frequency (PRF) and total dose, as well as the effects of ghosting. There was an over-response of the EPID signal compared to the ionization chamber of up to 18%, with no additional buildup layer over an air gap range of 10 to 60 cm. The addition of a 2.5 mm thick copper plate sufficiently reduced this over-response to within 1% at clinically relevant patient-detector air gaps (> 40 cm). The response of the EPIDs varied by up to 8% over a large range of dose per pulse values, PRF values and number of monitor units. The EPID response showed an under-response at shorter beam times due to ghosting effects, which depended on the number of exposure frames for a fixed frame acquisition rate. With an appropriate build-up layer and corrections for dose per pulse, PRF and ghosting, the variation in the a-Si EPID response can be reduced to well within +/- 1%.Keywords
This publication has 29 references indexed in Scilit:
- Three‐dimensional dose reconstruction of breast cancer treatment using portal imagingMedical Physics, 2003
- Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging devicePhysics in Medicine & Biology, 2002
- Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fieldsRadiotherapy and Oncology, 2001
- An iterative algorithm for reconstructing incident beam distributions from transmission measurements using electronic portal imagingPhysics in Medicine & Biology, 2001
- In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motionPublished by Elsevier ,1998
- Calibration of a portal imaging device for high‐precision dosimetry: A Monte Carlo studyMedical Physics, 1998
- First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane doseRadiotherapy and Oncology, 1998
- New Method to Obtain the Midplane Dose Using Portal In Vivo DosimetryInternational Journal of Radiation Oncology*Biology*Physics, 1998
- Analysis and convergence of the iterative convolution/superposition dose reconstruction technique for multiple treatment beams and tomotherapyMedical Physics, 1997
- Transmission dosimetry with a liquid-filled electronic portal imaging deviceInternational Journal of Radiation Oncology*Biology*Physics, 1996