Aortic Valve Replacement with Frame-Supported Autologous Fascia Lata Grafts:I. Technical Considerations and Early Results
- 1 January 1975
- journal article
- Published by Taylor & Francis in Scandinavian Journal of Thoracic and Cardiovascular Surgery
- Vol. 9 (2) , 94-107
- https://doi.org/10.3109/14017437509139182
Abstract
During the period November 1969 to June 1972, a frame-supported autologous fascia lata graft was implanted in 71 consecutive patients with surgically treated aortic valve disease at the Department of Thoracic & Cardiovascular Surgery, University Hospital, Uppsala. The follow-up period was between 1 and 4 years. Eleven patients died within 28 days of the operation (16 %) and 13 after discharge from hospital (18%); the cumulative mortality was thus 34%. Forty-five percent of the patients who died had associated cardiovascular or other diseases. The causes of death were infection (10), myocardial failure (6), myocardial infarction (3), cerebral damage (3), and intraoperative aortic dissection from the cannulation site (2). The majority of the deaths (88 %) occurred within 6 months and all within 131/2 months after operation. Two fascia lata valves were removed because of endocarditis 23 and 26 months, respectively, after operation. Two valves were also removed on account of mechanical malfunction. The remaining 44 patients with fascia lata valves showed clinical improvement at follow-up and 77 % of them had returned to work. No embolic complications occurred, despite the fact that only patients with a concomitant prosthetic mitral valve or atrial fibrillation received anticoagulant treatment. Haemodynamic studies of the valve in vitro and pressure measurements during the operation showed that the valve had a low primary systolic peak gradient of 0—16 mmHg. Certain modifications in the construction aimed at improving the haemodynamic properties of the valve are discussed. Increased stringency in the sterility precautions during the valve construction procedure may have contributed to the fact that early endocarditis, which is a serious complication, did not occur in any of the last 43 patients. As yet the observation time is too short to judge, however, to what extent susceptibility to infection and possible late changes of the valve can affect its function.Keywords
This publication has 13 references indexed in Scilit:
- Aortic Valve Replacement with Frame-Supported Autologous Fascia Lata Grafts:III. Haemodynamic and Angiographic FindingsScandinavian Journal of Thoracic and Cardiovascular Surgery, 1975
- Aortic Valve Replacement with Frame-Supported Autologous Fascia Lata Grafts:II. Clinical and Laboratory FindingsScandinavian Journal of Thoracic and Cardiovascular Surgery, 1975
- Late Changes in Formalin-Treated Porcine Aortic Heterografts Replacing Human Mitral Valves:A Pathological StudyScandinavian Journal of Thoracic and Cardiovascular Surgery, 1975
- Postoperative Changes in Autologous Fascia Lata Heart Valve Grafts: A Pathological StudyThe Annals of Thoracic Surgery, 1973
- Heart Valve Replacement with Aortic HeterograftsThe Annals of Thoracic Surgery, 1972
- A new central flow pivoting disc aortic and mitral prosthesis: Initial clinical experienceThe American Journal of Cardiology, 1970
- Replacement of heart valves with autologous fascia lata. Surgical techniqueBritish Journal of Surgery, 1970
- HEART-VALVE REPLACEMENT WITH AUTOLOGOUS FASCIA LATAThe Lancet, 1969
- Results Of Aortic Valve Replacement With The Kay-Shiley Disc ValveScandinavian Journal of Thoracic and Cardiovascular Surgery, 1969
- A New Tilting Disc Valve ProsthesisScandinavian Journal of Thoracic and Cardiovascular Surgery, 1969